Sound system equipment – Part 21: Acoustical (output-based) measurements
Introduction: Loudspeakers, headphones and other actuators have become more versatile and, as a result, new measurement techniques are required to evaluate these systems. The following is a list of examples where new measurement techniques are required: Limited access to the electrical terminals of the transducer The higher integration of electrical, acoustical and mechanical elements limit the access to the electrical terminals of the transducer. Analogue or digital audio input signals Audio inputs can accept analogue or digital signals in various formats. Latency and other kinds of distortion associated with digital signal processing Digital signal processing is used to correct the transfer behaviour of the passive system and to generate a desired sound output and as a result, latency and other kinds of distortion not found in analogue equipment can be generated. Excessive equalization Excessive equalization can force the transducer to operate in the large signal domain causing thermal and nonlinear effects. Active protection Active protection attenuates the input signal to prevent a mechanical and thermal overload of the transducer and other components. Other transducer principles Although most loudspeaker systems use a moving coil in an electro-dynamical transducer, there is a need to expand the application to electro-static, electro-magnetic or any other transduction principles. Other mechanical and acoustical elements To improve sound radiation, vented enclosures, sealed enclosures,
Scope: This part of IEC 60268 specifies an acoustical measurement method that applies to electro- acoustical transducers and passive and active sound systems, such as loudspeakers, TV-sets, multi-media devices, personal portable audio devices, automotive sound systems and professional equipment. The device under test (DUT) can be comprised of electrical components performing analogue and digital signal processing prior to the passive actuators performing a transduction of the electrical input into an acoustical output signal. This document describes only physical measurements that assess the transfer behaviour of the DUT between an arbitrary analogue or digital input signal and the acoustical output at any point in the near and far field of the system. This includes operating the DUT in both the small and large signal domains. The influence of the acoustical boundary conditions of the target application (e.g. car interior) can also be considered in the physical evaluation of the sound system. This document does not assess the perception and cognitive evaluation of the reproduced sound and the impact of perceived sound quality. NOTE Some measurement methods defined in this document can be applied to headphones, headsets, earphones and earsets in accordance with [1]1. This document does not apply to microphones and other sensors. This document does not require access to the state variables (voltage, current) at the electrical terminals of the transducer. Sensitivity, electric input power and other characteristics based on the electrical impedance will be described in a separate future standard document, IEC 60268-22, dedicated to electrical and mechanical measurements.
Contents:
- FOREWORD
- INTRODUCTION
- Scope