Electric cables-Calculation of the current rating-Part 2-3: Thermal resistance-Cables installed in ventilated tunnels

$171.50 $342.99 -50%
Product Code: IEC 60287-2-3 (REDLINE + STANDARD)
Stock In Stock
Edition: 2.0
Published: 06/2024
Number of Pages: 60
File Size: 1 file, 1.1 MB

Available Options

Product Description

Electric cables – Calculation of the current rating – Part 2-3: Thermal resistance – Cables installed in ventilated tunnels

Introduction: In the IEC 60287 series, IEC 60287-1 provides general formulae for ratings and power losses of electric cables. The IEC 60287-2 series presents formulae or calculation methods for thermal resistances. IEC 60287-2-1 provides calculation methods for dealing with cables installed in free air (see IEC 60287-2-1:2015, 4.2.1). IEC 60287-2-2 provides a method and data for calculating reduction factors for cables in groups running horizontally in free air. IEC 60287-2-1 and IEC 60287-2-2 consider heat transfer only in a plane perpendicular to the cables; they assume there is no longitudinal heat transfer. This part of IEC 60287 deals with the rating for cables installed in ventilated tunnels. In such situations, consideration of longitudinal temperature gradients is involved as the air flowing in the tunnel removes some heat from the cables. Heat transfer with the moving air is convective and is assumed to be either laminar or turbulent depending on the air velocity. The transition situation between laminar and turbulent air flows is ignored. A general simplified method is provided to estimate the permissible current-carrying capacity of cables installed in ventilated tunnels, the ventilation being either natural or forced. Only steady states are considered, where the inlet air temperature and the cable loading are constant for a sufficient time for steady temperatures to be achieved. Where multiple circuits are involved, their characteristics are assumed to be identical. The main fe

Scope: This part of IEC 60287 describes a method for calculating the continuous current rating factor for cables of all voltages installed in ventilated tunnels. The method is applicable to any type of cable. The method applies to natural as well as forced ventilation. Longitudinal heat transfer within the cables and the surroundings of the tunnel is assumed to be negligible. All cables are assumed to be identical within the tunnel and it is assumed that the tunnel cross- section does not change with distance along the tunnel.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60287-2-3 (REDLINE + STANDARD)-2024 PDF

IEC 60287-2-3 (REDLINE + STANDARD)-2024 PDF

$171.50 $342.99