IEC 60332-1-2 CMV-2025 PDF

IEC 60332-1-2 CMV-2025 PDF

Tests on electric and optical fibre cables under fire conditions-Part 1-2: Test for vertical flame propagation for a single insulated wire or cable-Procedure for 1 kW pre-mixed flame (Commented Version)

$100.88 $201.76 -50%
Product Code: IEC 60332-1-2 CMV
Stock In Stock
Edition: 2.0
Published: 06/2025
Number of Pages: 30
File Size: 1 file, 620 KB

Available Options

Product Description

Tests on electric and optical fibre cables under fire conditions – Part 1-2: Test for vertical flame propagation for a single insulated wire or cable – Procedure for 1 kW pre-mixed flame (Commented Version)

Scope: This part of IEC 60332 specifies the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions using a 1 kW pre-mixed flame 1. The apparatus is described in IEC 60332-1-1. NOTE 1 Testing to IEC 60332-1-2 may can be performed simultaneously with that to IEC 60332-1-3, if required. Recommended requirements for performance are given in Annex A. IEC 60332-1-2 specifies the use of a 1 kW pre-mixed flame and is for general use, except that the procedure specified may not be suitable for the testing of small single insulated conductors or cables of less than 0,5 mm² total cross-section because the conductor melts before the test is completed, or for the testing of small optical fibre cables because the cable is broken before the test is completed. In these cases, the procedure given in IEC 60332-2-2 is recommended. 2 This group safety publication focusing on test method(s) is primarily intended to be used as a product safety standard for the products mentioned in the scope, but is also intended to be used by technical committees in the preparation of standards for products similar to those mentioned in the scope of this group safety publication, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51. NOTE 2 Since the use of insulated conductor or cable which retards flame propagation and complies with the recommended requirements of this standard is not sufficient by itself to prevent propagation of fire under all conditions of installation, it is recommended that wherever the risk of propagation is high, for example in long vertical runs of bunches of cables, special installation precautions should also be taken. It cannot be assumed that because the sample of cable complies with the performance requirements recommended in this standard, that a bunch of cables will behave in a similar manner. (See IEC 60332-3 series.) The performing of this test method on a single insulated conductor or cable or optical fibre cable does not provide compliance with fire propagation requirements in relevant standards in the case that the single

Contents:

  • FOREWORD
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60332-1-2 CMV-2025 PDF

IEC 60332-1-2 CMV-2025 PDF

$100.88 $201.76