Low-voltage electrical installations – Part 5-54: Selection and erection of electrical equipment – Earthing arrangements and protective conductors
Introduction: Clause numbering is sequential, preceded by the number of this Part. Numbering of figures and tables takes the number of this part followed by a sequential number, i.e. Table 54.1, 54.2, etc. Numbering of figures and tables in annexes takes the letter of the annex, followed by the number of the part, followed by a sequential number, e.g. A.54.1, A.54.2, etc. To define a clear borderline between functional earthing and protective earthing the following explanations are given: Functional earthing Functional earthing If any connection of the functional earthing is interrupted, it does not impair any kind of protection or any kind of protective measure or protective provision provided for electrical safety. Therefore, its application mainly relates to: communication, measurement, and EMC as regards radiated disturbances and conducted high frequency disturbances. Protective earthing If any connection of the protective earthing is interrupted, it impairs the protection or the function of a protective measure or protective provision provided for electrical safety. Requirement for protective earthing are given in: IEC 60364-4-41 for protection against electric shock; IEC 60364-4-42 for protection against thermal effects; IEC 60364-4-44 for protection against conducted disturbances. INTRODUCTION to Amendment 1 The main changes provided in this Amendment 1 are: clarification and necessary modifications to define a clear borderline between functional earthing and protective earthing (se
Scope: This part of IEC 60364 addresses the earthing arrangements and protective conductors including protective bonding conductors in order to satisfy the safety of the electrical installation. This document also includes requirements regarding earthing and equipotential bonding for information and communication technology (ICT) with the aim of: reducing the risk of electrical hazards for correct operation of these devices and the information and communication technology wiring; providing the telecommunication systems with a reliable signal reference plane that can improve resistance to electromagnetic interference (EMI) by reference to ISO/IEC 30129. NOTE Examples of information and communication technology (ICT) include: DC supply networks (and systems) for supplying power to ICT equipment within a building; star-shaped private automatic branch exchanges (PABX) or their equipment; local area (communication) networks (LANs); fire and intruder alarms communication systems; building automation systems, e.g. direct digital control systems; systems for computer-aided manufacturing (CAM) and other computer-aided services; broadcast and communication technology. 541.2
Contents:
- FOREWORD
- INTRODUCTION
- 541 General
- 541.1 Scope
- 541.2 Normative references
- 541.3 Terms and definitions
- 542 Earthing arrangements
- 542.1 General requirements
- 542.2 Earth electrodes
- 542.3 Earthing conductors
- 542.4 Main earthing terminal
- 543 Protective conductors
- 543.1 Minimum cross-sectional areas
- 543.2 Types of protective conductors
- 543.3 Electrical continuity of protective conductors
- 543.4 PEN, PEL or PEM conductors
- 543.5 Combined protective and functional earthing conductors
- 543.6 Currents in protective earthing conductors
- 543.7 Reinforced protective earthing conductors for protective earthing conductor
- 543.8 Arrangement of protective conductors
- 544 Protective bonding conductors
- 544.1 Protective bonding conductors for connection to the main earthing terminal
- 544.2 Protective bonding conductors for supplementary bonding
- 545 Functional earthing and functional-equipotential-bonding for Information and
- 545.1 Functional-equipotential-bonding for ICT
- 545.2 Main functional earthing terminal (MFET)
- 545.3 Equipotential bonding ring conductors