Underwater acoustics – Hydrophones – Calibration of hydrophones – Part 1: Procedures for free-field calibration of hydrophones
Introduction: Underwater acoustic measurements are made to provide validation and qualification in a wide range of ocean applications, including oceanography, defence, fisheries, geophysics and in developments in the off-shore energy industries. In addition, the increasing concern about the effect of anthropogenic sound on the marine environment has led to regulation which requires absolute acoustic measurement of the sound radiated by specific sources, and of the ambient sound field. To be meaningful, it is important that measurements be performed in a technically sound manner, be related to common standards of measurement, and be made using calibrated sensors. Hydrophones are the most commonly-used sensor to measure sound in the ocean. It is important that the hydrophones used to measure sound pressure are calibrated using agreed standard methodologies, with valid uncertainties. The purpose of this document is to establish procedures for calibration under free-field conditions of hydrophones used in underwater acoustics for ocean applications. Also covered are calibration procedures for individual underwater electroacoustic transducers which can be used as a hydrophone and/or source transducer. Principles, procedures, and sources of uncertainty are also provided in this document. The calibration methods described include absolute methods which do not require an acoustic reference transducer, and relative methods which make use of a calibrated acoustic reference hydrophone or projector. T
Scope: This part of IEC 60565 specifies methods and procedures for free-field calibration of hydrophones, as well as individual electroacoustic transducers that can be used as hydrophones (receivers) and/or projectors (source transducers). Two general types of calibration are covered within this document: absolute calibration using the method of three- transducer spherical-wave reciprocity, and relative calibration by comparison with a reference device which has already been the subject of an absolute calibration. The maximum frequency range of the methods specified in this document is from 200 Hz to 1 MHz. The lowest acoustic frequency of application will depend on a number of factors, and will typically be in the range 200 Hz to 5 kHz depending mainly on the dimensions of the chosen test facility, The highest frequency of application for the methods described here is 1 MHz. Procedures for pressure hydrophone calibration at low frequencies can be found in IEC 60565-2 [1]1. Procedures for hydrophone calibration at acoustic frequencies greater than 1 MHz are covered by IEC 62127-2 [2]. Excluded from the scope of this document are low-frequency pressure calibrations of hydrophones, which are described in IEC 60565-2 [1]. Also excluded are calibrations of digital hydrophones and systems, calibration of marine autonomous acoustic recorders, calibration of acoustic vector sensors such as particle velocity sensors and pressure gradient hydrophones, calibration of passive sonar arrays consisting of multiple hydrophones, and calibration of active sonar arrays consisting of projectors and hydrophones. This document presents a description of the requirements for free-field calibration in terms of test facility, equipment and instrumentation, signal processing, and frequency limitations. A description of achievable uncertainty and rules for the presentation of the calibration data are provided. Also included are informative annexes that provide additional guidance on measurement of directional response of a hydrophone or projector, measurement of electrical impedance of hydrophones and projectors, electrical loading corrections, acoustic far-field criteria in underwater acoustic
Contents:
- FOREWORD
- INTRODUCTION
- Scope