Thermocouples – Part 1: EMF specifications and tolerances
Introduction: This International Standard relates the electromotive force (hereafter abbreviated as EMF) generated by the designated thermocouple types to temperature, based upon the International Temperature Scale of 1990 (ITS-90). The reference polynomials for Types R, S, B, J, T, E, K and N are those used in the previous edition of this standard, IEC 60584-1:19951. They were originally produced by the National Institute of Standards and Technology of the USA and published in NIST Monograph 175, 1993. The major revision of this version is standardization of two kinds of tungsten-rhenium thermocouple, designated Type C and Type A. Both of them have been used in industry for a long time. Temperature versus EMF relationships for Type C and Type A are those published in the ASTM E230/E230-M12 and GOST R 8.585-2001 standards, respectively. This edition merges two parts of the former IEC 60584 series, IEC 60584-1:1995 (Reference tables) and IEC 60584-2:1982 (Tolerances) and supersedes both standards. IEC 60584-3:2007 remains valid. ————————— 1 See Bibliography.
Scope: This part of IEC 60584 specifies reference functions and tolerances for letter-designated thermocouples (Types R, S, B, J, T, E, K, N, C and A). Temperatures are expressed in degrees Celsius based on the International Temperature Scale of 1990, ITS-90 (symbol t90), and the EMF (symbol E) is in microvolts. The reference functions are polynomials which express the EMF, E in µV, as a function of temperature t90 in °C with the thermocouple reference junctions at 0 °C. Values of EMF at intervals of 1 °C are tabulated in Annex A. For convenience of calculating temperatures, inverse functions are given in Annex B which express temperature as functions of EMF within stated accuracies. This International Standard specifies the tolerances for thermocouples manufactured in accordance with this standard. The tolerance values are for thermocouples manufactured from wires, normally in the diameter range 0,13 mm to 3,2 mm, as delivered to the user and do not allow for calibration drift during use. Annex C gives guidance on the selection of thermocouples with regard to temperature range and environmental conditions. Terms and definitions For the purposes of this document, the following terms and definitions apply. 2.1 thermoelectric effect Seebeck effect production of an electromotive force (EMF) due to a temperature gradient along a conductor 2.2 Seebeck coefficient of a thermocouple change in EMF of a thermocouple combination per unit of temperature change, being the first derivative of EMF with respect to temperature. Note 1 to entry: The Seebeck coefficient dE/dt90, is expressed in µV/°C. 2.3 thermocouple pair of conductors of dissimilar materials joined at one end and forming part of an arrangement using the thermoelectric effect for temperature measurement 2.4 measuring junction junction of the thermocouple subjected to the temperature to be measured – 70 – 60584-1 © CEI:2013 AVANT-PROPOS .................................................................................................................. 72 INTRODUCTION ................................................................................................................... 74 Domaine d'application ................
Contents:
- FOREWORD
- INTRODUCTION
- Scope