IEC 60601-2-11-2013 PDF

IEC 60601-2-11-2013 PDF

Medical electrical equipment-Part 2-11: Particular requirements for the basic safety and essential performance of gamma beam therapy equipment

$186.00 $371.99 -50%
Product Code: IEC 60601-2-11
Stock In Stock
Edition: 3.0
Published: 01/2013
Number of Pages: 104
File Size: 1 file, 793 Bytes

Available Options

Product Description

Medical electrical equipment – Part 2-11: Particular requirements for the basic safety and essential performance of gamma beam therapy equipment

Introduction: The use of GAMMA BEAM THERAPY EQUIPMENT for RADIOTHERAPY purposes may expose PATIENTS to danger if the ME equipment fails to deliver the required dose to the PATIENT, or if the ME equipment design does not satisfy standards of electrical and mechanical safety. The ME EQUIPMENT may also cause danger to persons in the vicinity if the ME equipment itself fails to contain the RADIATION adequately or if there are inadequacies in the design of the TREATMENT ROOM. This particular standard establishes requirements to be complied with by MANUFACTURERS in the design and construction of gamma beam therapy equipment. Subclause 201.10.2 states tolerance limits beyond which INTERLOCKS must prevent, INTERRUPT or TERMINATE IRRADIATION in order to avoid an unsafe condition. TYPE TESTS which are performed by the MANUFACTURER, or SITE TESTS, which are not necessarily performed by the MANUFACTURER, are specified for each requirement. Subclause 201.10.2 does not attempt to define the optimum performance requirements for a GAMMA BEAM THERAPY EQUIPMENT for use in RADIOTHERAPY. Its purpose is to identify those features of design which are regarded at the present time as essential for the safe operation of such ME EQUIPMENT. It places limits on the degradation of ME EQUIPMENT performance at which it can be presumed that a fault condition applies, e.g. a component failure, and where an INTERLOCK then operates to prevent continued operation of the ME EQUIPMENT. It should be understood that, before inst

Scope: 201.1. Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of GAMMA BEAM THERAPY EQUIPMENT, including MULTI-SOURCE STEREOTACTIC RADIOTHERAPY equipment, hereafter referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. NOTE See also 4.2 of the general standard. Object 201.1. Replacement: The object of this particular standard is to establish particular BASIC SAFETY and ESSENTIAL PERFORMANCE requirements for GAMMA BEAM THERAPY EQUIPMENT. Collateral standards 201.1. Addition: This particular standard refers to those applicable collateral standards that are listed in Clause 2 of the general standard and Clause 201.2 of this particular standard. IEC 60601-1-3 and IEC 60601-1-10 do not apply. All other published collateral standards in the IEC 60601-1 series apply as published. _______________ 1 The general standard is IEC 60601-1:2005, Medical electrical equipment – Part 1: General requirements for basic safety and essential performance. 60601-2-11 © IEC:2013 – 7 – Particular standards 201.1. Replacement: In the IEC 60601 series, particular standards may modify, replace or delete requirements contained in the general standard and collateral standards as appropriate for the particular ME EQUIPMENT under consideration, and may add other BASIC SAFETY and ESSENTIAL PERFORMANCE requirements. A requirement of a particular standard takes priority over the general standard. For brevity, IEC 60601-1 is referred to in this particular standard as the general standard. Collateral standards are referred to by their document number. The numbering of clauses and subclauses of this particular standard corresponds to that of the general standard with the prefix “

Contents:

  • FOREWORD
  • INTRODUCTION
  • 201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTESM (PEMS)

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60601-2-11-2013 PDF

IEC 60601-2-11-2013 PDF

$186.00 $371.99