IEC 60601-2-12-2001 PDF

IEC 60601-2-12-2001 PDF

Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Lung Ventilators - Critical Care Ventilators

$186.00 $371.99 -50%
Product Code: IEC 60601-2-12
Stock In Stock
Edition: 2.0
Published: 10/2001
Number of Pages: 48
File Size: 1 file, 393 Bytes

Available Options

Product Description

Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Lung Ventilators - Critical Care Ventilators

Introduction: Critical care VENTILATORS are an essential medical device in every intensive care unit (ICU). Approximately half of all PATIENTS in ICUs receive partial to full ventilatory support with this EQUIPMENT. Given the vulnerable status of these PATIENTS, EQUIPMENT safety is of fundamental importance. Accordingly, this Particular Standard, by building on other standards and specifically on IEC 60601-1: Medical electrical equipment – Part 1: General requirements for safety, herein referred to as the “General Standard”, sets the minimum requirements that should be met by every critical care VENTILATOR that is designed after the publication of this Particular Standard. A rationale for the most important requirements is given in Annex AA. Continuous positive airway pressure (CPAP) devices, sleep apnea therapy devices, support- care VENTILATORs, anaesthesia, emergency and transport VENTILATORs, jet and high frequency VENTILATOR and oscillators are not covered by this Particular Standard, nor are devices that may be used within hospitals, intended solely to augment the ventilation of spontaneously breathing PATIENTS.

Scope: Addition: This Particular Standard specifies the safety requirements for VENTILATORS, as defined in 2.1.125, intended for use in critical care settings. Continuous positive airway pressure (CPAP) devices, sleep apnea therapy devices, support- care VENTILATORs, emergency and transport VENTILATORs, jet and high frequency VENTILATORs and oscillators are outside the scope of this Particular Standard, nor are devices that may be used within hospitals, intended solely to augment the ventilation of spontaneously breathing PATIENTS. Standards for other types of VENTILATORs, e.g. high frequency jet and oscillation ventilators, are under consideration. Requirements for VENTILATORs intended for anaesthetic applications are given in IEC 60601-2-13. 1.2 Object Addition: The object of this standard is to specify particular safety requirements for VENTILATORS intended for use in critical care settings. 1.3 Particular standards Addition: This Particular Standard refers to IEC 60601-1:1988, Medical electrical equipment – Part 1: General requirements for safety, as amended by its amendment 1 (1991) and its amendment 2 (1995), herein referred to as the “General Standard”. The General Standard takes into account a set of Collateral Standards: IEC 60601-1-1:2000, Medical electrical equipment – Part 1-1: General requirements for safety, Collateral standard: Safety requirements for medical electrical systems IEC 60601-1-2:2001, Medical electrical equipment – Part 1-2: General requirements for safety – Collateral standard: Electromagnetic compatibility – Requirements and tests – 8 – 60601-2-12 © IEC:2001(E) IEC 60601-1-4:1996, Medical electrical equipment – Part 1: General requirements for safety, 4. Collateral standard: Programmable electrical medical systems Amendment 11 The term “this Standard” covers this Particular Standard, used together with the General Standard and the Collateral Standards. The numbering of sections, clauses, and subclauses of this Particular Standard corresponds with that of the General Standard. The changes to the text of the General Standard are specified by the use of the following words: “Replacement” means that the clause or subclause of the General Stand

Contents:

  • FOREWORD
  • INTRODUCTION

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60601-2-12-2001 PDF

IEC 60601-2-12-2001 PDF

$186.00 $371.99