IEC 60601-2-28 (REDLINE + STANDARD)-2017 PDF

IEC 60601-2-28 (REDLINE + STANDARD)-2017 PDF

Medical electrical equipment-Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis

$171.50 $342.99 -50%
Product Code: IEC 60601-2-28 (REDLINE + STANDARD)
Stock In Stock
Edition: 3.0
Published: 06/2017
Number of Pages: 78
File Size: 1 file

Available Options

Product Description

Medical electrical equipment – Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis

Scope: Replacement: This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of X-RAY TUBE ASSEMBLIES and to components thereof, hereafter referred to as ME EQUIPMENT, intended for medical diagnosis and imaging. Where the general standard IEC 60601-1 and the collateral standard IEC 60601-1-3 refer to ME EQUIPMENT, this is interpreted as X-RAY TUBE ASSEMBLIES in this particular standard. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. NOTE This document is also applicable to the X-RAY TUBE ASSEMBLY aspects of X-RAY SOURCE ASSEMBLIES and X- RAY TUBE HEADS. 201.1.2 Object Replacement: The object of this particular standard is to establish particular BASIC SAFETY and ESSENTIAL PERFORMANCE requirements for X-RAY TUBE ASSEMBLIES for medical diagnosis. 201.1.3 Collateral standards Addition: This particular standard refers to those applicable collateral standards that are listed in Clause 2 of the general standard and Clause 201.2 of this particular standard. IEC 60601-1-3:2008 and IEC 60601-1-3:2008/AMD1:2013 apply as modified in Clause 203. IEC 60601-1-2, IEC 60601-1-6, IEC 60601-1-8, IEC 60601-1-9, IEC 60601-1-10, IEC 60601-1- 11 and IEC 60601-1-12 do not apply. All other published collateral standards in the IEC 60601-1 series apply as published. NOTE 101 IEC 60601-1-2 does not apply because RISKS for the X-RAY TUBE ASSEMBLY outside the system may only be indicative of RISKS for the system due to the difference in electromagnetic environment. NOTE 102 IEC 60601-1-6 and IEC 60601-1-8 do not apply because X-RAY TUBE ASSEMBLIES are not operated as a stand-alone device. ___________ The general standard is IEC 60601-1:2005 and IEC 60601-1:2005/AMD1:2012, Medical electrical equipment – Part 1: General requirements for basic safety and essential performance. IEC 60601-2-28:2017 RLV  IEC 2017 – 7 – NOTE 103 X-RAY TUBE ASSEMBLIES are not in the scope of IEC 60601-1-10, IEC 60601-1-11 and IEC 60601-1-12. 201.1.4 Particular standa

Contents:

  • FOREWORD

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60601-2-28 (REDLINE + STANDARD)-2017 PDF

IEC 60601-2-28 (REDLINE + STANDARD)-2017 PDF

$171.50 $342.99