Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells
Introduction: Traditionally the manufacturers and users of alkaline secondary cells and batteries have expressed the current used to charge and discharge these cells and batteries as a multiple of the capacity. For example, a current of 20 A used to charge a cell with a rated capacity (C Ah) of 100 Ah would be expressed as C/5 A or 0,2 C A. This method of current designation has been used in earlier standards relating to alkaline secondary cells and batteries. Comments have been made, however, that this method of current designation is dimensionally incorrect, in that a multiple of the capacity (ampere-hours) will be in ampere- hours and not, as required for current, in amperes. As a result of these comments, the method described in IEC 61434 has been used in this standard. In brief, the method states that the reference test current (It) is expressed as: Ah where Cn is the rated capacity declared by the manufacturer in ampere-hours (Ah), and is the time base in hours (h) for which the rated capacity is declared.
Scope: IEC 60623 specifies marking, designation, dimensions, tests and requirements for vented nickel-cadmium prismatic secondary single cells. NOTE In this context, "prismatic" refers to cells having rectangular sides and base. When there exists an IEC standard specifying test conditions and requirements for cells used in special applications and which is in conflict with this document, the former shall takes precedence.
Contents:
- FOREWORD
- INTRODUCTION
- Scope