Electroacoustics – Audiometric equipment – Part 1: Equipment for pure-tone and speech audiometry
Introduction: Developments in the field of hearing measurements for diagnostic, hearing conservation and rehabilitation purposes have resulted in the availability of a wide range of audiometers. In addition it is possible to consider the audiometer in terms of a set of functional units which can be specified independently. By specifying these functional units it is then possible to specify the performance of other audiometric equipment which use these units. The IEC 60645 series consists of a number of parts. IEC 60645-1 is the first in the series and covers the requirements for both pure-tone and speech audiometers. This standard describes the performance requirements for pure-tone audiometers, which are designed for the measurement of hearing in the frequency range from 125 Hz to 16 kHz, and speech audiometers, which are designed for performing live or recorded speech audiometry. When speech signal facilities are provided by an audiometer, performance requirements are given for both live voice and recorded speech material. Although live voice speech audiometry may not be capable of meeting the requirements of this standard, it is widely practiced, particularly with children, and therefore a specification is included in order to ensure as high a degree of reliability as possible. This standard does not specify the speech material that is used for test purposes or the required acoustic properties of the test room.1 Speech audiometers use earphones or loudspeakers to present signals to the
Scope: This part of IEC 60645 specifies general requirements for audiometers designed for use in determining hearing threshold levels, relative to standard reference threshold levels established by means of psychoacoustic test methods, and those designed to perform psychoacoustic tests using speech material. The object of this standard is to ensure: a) that tests of hearing in the frequency range 125 Hz to 16 kHz on a given human ear, performed with different pure-tone audiometers which comply with this standard, give substantially the same results; b) that the results obtained represent a valid comparison between the hearing of the ear tested and the reference threshold of hearing; c) that a means of presenting speech material to a subject in a standardized manner is provided. This will ensure that tests of hearing using a specific speech signal and a specific manner of signal presentation, when performed with different audiometers which comply with this standard, give substantially the same results; d) that audiometers are classified according to the range of test signals they present, according to the mode of operation or according to their presumed primary application.
Contents:
- FOREWORD
- INTRODUCTION
- Scope