Fire hazard testing – Part 7-1: Toxicity of fire effluent – General guidance
Introduction: Electrotechnical products sometimes become involved in fires. However, except for certain specific cases (for example, power generating stations, mass transit tunnels, computer suites), electrotechnical products are not normally present in sufficient quantities to form the major source of toxic hazard. For example, in domestic dwellings and places of public assembly, electrotechnical products are usually a very minor source of fire effluent compared with, for example, furnishings. The IEC 60695-7 series of publications is subject to the ongoing evolution of fire safety philosophy within ISO TC 92. The guidance in this International Standard is consistent with the principles of fire safety developed by ISO TC 92 (SC 3) on toxic hazards in fire as described in ISO 19706. General guidance for the fire hazard assessment of electrotechnical products is provided in IEC 60695-1-10 and IEC 60695-1-11. Guidance on the estimation of escape times from fires is provided in ISO 13571. The determination of the lethal toxic potency of fire effluents is described in ISO 13344. In 1989, the following views were expressed in ISO/TR 9122-1. "Small-scale toxic potency tests as we know them today are inappropriate for regulatory purposes. They cannot provide rank orderings of materials with respect to their propensity to produce toxic atmospheres in fires. All currently available tests are limited because of their inability to replicate the dynamics of fire growth which determine the time/concent
Scope: This part of IEC 60695 provides guidance on the factors which affect the toxic hazard from fires involving electrotechnical products, and provides information on the methodologies recommended by ISO TC 92 (SC 3) for estimating and reducing the toxic hazard from fires, as expressed in ISO 19706, ISO 13344 and ISO 13571. There is no single test to realistically assess toxic hazard in fires. Small-scale toxic potency tests are not capable on their own of assessing the toxic hazard in fires. Current toxicity tests attempt to measure the toxic potency of a laboratory generated fire effluent. Toxic potency should not be confused with toxic hazard. This basic safety publication is intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 104 and ISO/IEC Guide 51. One of the responsibilities of a technical committee is, wherever applicable, to make use of basic safety publications in the preparation of its publications. The requirements, test methods or test conditions of this basic safety publication will not apply unless specifically referred to or included in the relevant publications.
Contents:
- FOREWORD
- INTRODUCTION
- Scope