Medical electrical equipment - Dosimeters with ionization chambers as used in radiotherapy
Introduction: This International Standard is applicable to the performance of RADIOTHERAPY DOSIMETERS with IONIZATION CHAMBERS as used in RADIOTHERAPY. The effectiveness of treatment of PATIENTS receiving RADIOTHERAPY depends on the accuracy of the dose of radiation received, as well as on the accuracy of their spatial distribution. An excessive dose can lead to excessive tissue damage, while an insufficient dose will not provide the therapeutic benefit sought. The equipment covered by this standard plays an essential part in achieving the required accuracy. This standard is not concerned with the safety aspects of dosimeters. The relevant IEC standards covering safety depend upon the way in which the dosimeter is used: if it is used in the PATIENT environment, the requirements for safety applying to dosimeters with IONIZATION CHAMBERS as used in RADIOTHERAPY are contained in IEC 60601-1; if it is not used in the PATIENT environment, then the safety requirements for dosimeters with IONIZATION CHAMBERS as used in RADIOTHERAPY are contained in IEC 61010-1. Dosimeters which comply with this standard should nevertheless be used in accordance with the relevant national or international dosimetry protocol (code of practice). In particular, measurements should be made to determine the ion collection efficiency and polarity effect of the chamber under the exact conditions of use.
Scope: This International Standard specifies the performance requirements of RADIOTHERAPY DOSIMETERS, intended for the measurement of ABSORBED DOSE TO WATER or AIR KERMA (and their rates and spatial distributions) in PHOTON, ELECTRON, proton or heavy ion RADIATION FIELDS as used in RADIOTHERAPY. The DOSE MONITORING SYSTEMS incorporated in RADIOTHERAPY treatment machines are not covered by this standard, neither are the re-entrant IONIZATION CHAMBERS used for BRACHYTHERAPY source calibration and constancy check devices. This standard is applicable to the following types of dosimeter: a) FIELD-CLASS DOSIMETERS normally used for 1) the measurement of KERMA or dose in a RADIATION BEAM, either in air or in a PHANTOM; 2) in vivo skin surface or intracavitary measurements of dose on PATIENTS. b) REFERENCE-CLASS DOSIMETERS normally used for the calibration of FIELD-CLASS DOSIMETERS; NOTE REFERENCE-CLASS DOSIMETERS may be used as FIELD-CLASS DOSIMETERS. c) SCANNING-CLASS DOSIMETERS normally used for relative dose distribution measurements with a SCANNING SYSTEM such as an automatic water PHANTOM. 1.2 Object The object of this standard is: to establish requirements for a satisfactory level of performance for RADIOTHERAPY DOSIMETERS; to standardize methods for the determination of compliance with this level of performance. Three levels of performance are specified: a lower level of performance applying to FIELD-CLASS DOSIMETERS; a higher level of performance applying to REFERENCE-CLASS DOSIMETERS; a specific level of performance applying to SCANNING-CLASS DOSIMETERS.
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 5.2.10 Cable microphony
- 5.2.11 Polarity of polarizing voltage effect
- 5.2.12 ELECTROMAGNETIC COMPATIBILITY