Semiconductor Devices - Integrated Circuits - Part 23-2: Hybrid Integrated Circuits and Film Structures - Manufacturing Line Certification - Internal Visual Inspection and Special Tests
Introduction: This set of specifications prescribes a set of procedures to be used by users and manu- facturers for the production and delivery of high-quality, special requirement hybrid integrated circuits and film structures with a specified level of quality and reliability. This set of specifications prescribes reference criteria for the establishment, control, maintenance and development of a certified manufacturing line and represents a manufacturing line certification methodology. The targeted level of quality and reliability is to be achieved by using best design and manufacturing practices. Examples of quality and reliability best practices for elimination of potential failure mechanisms and achievement of a targeted quality and reliability level include: material characterization for derivation of process design rules, in-process control, continuous improvement, etc. Assessment (estimation) of the targeted quality and reliability level may be accomplished by: a) using data obtained from the material characterization, design and process control and improvement activities; or b) through the use of product assessment level schedule (PALS) tests. Part 23-1 of this set of specifications provides general information. Part 23-3 of this set of specifications provides a framework for use as an assessment/audit tool to assist the suppliers, customers or an independent organization to carry out an assessment of a certified manufacturing line of a hybrid manufacturing company. Part 23-4 of t
Scope: This part of IEC 60748 applies to high quality approval systems for hybrid integrated circuits and film structures. The purpose of the tests is to perform visual inspections on the internal materials, construction and workmanship of hybrid, multichip and multichip module microcircuits and passive elements used for microelectronic applications including r.f./microwave. These tests are for both Class H and Class K quality levels, SAW and film hybrid/multichip/ multichip module microcircuits using substrates such as ceramic and silicon. Class K is applicable to all microcircuits released to product assessment level schedule 11 (e.g. for space applications – see IEC 60748-23-1). Class H is applicable to all other microcircuits released to this standard. The following types of microcircuits may be inspected: a) passive thin and thick film networks; b) active thin and thick film circuits; c) multiple circuits, including combinations, stacking or other interconnections of 1 a) and 1 b). Where the deposited film has geometric features larger than 25 µm, the inspection criteria defined in clause 5 apply. In cases where deposited features are smaller than this (e.g. deposited integrated circuits) the inspection requirements of IEC 60747 shall be applied. These tests will normally be used on microelectronic devices prior to capping or encapsulation to detect and eliminate devices with internal non-conformances that could lead to device failure in normal application. They may also be employed on a sampling basis to determine the effectiveness of the manufacturers’ quality control and handling procedures.
Contents:
- FOREWORD
- INTRODUCTION
- Scope