Calculation of the Cyclic and Emergency Current Rating of Cables Part 3: Cyclic Rating Factor for Cables of all Voltages, with Partial Drying of the Soil

$50.44 $100.88 -50%
Product Code: IEC 60853-3
Stock In Stock
Edition: 1.0
Published: 02/2002
Number of Pages: 38
File Size: 1 file, 511 Bytes

Available Options

Product Description

Calculation of the Cyclic and Emergency Current Rating of Cables Part 3: Cyclic Rating Factor for Cables of all Voltages, with Partial Drying of the Soil

Introduction: Methods for calculating cyclic ratings for cables installed in the ground are given in IEC 60853-1 and IEC 60853-2. Part 1 is applicable to cables having negligible thermal capacitance; Part 2 is applicable to cables where their thermal capacitance cannot be neglected. A fundamental assumption in Part 1 and Part 2 is that the thermal properties of the soil are uniform throughout the thermal field of the cable. For many installations, such an assumption is acceptable and further refinement is unnecessary. However, higher working temperatures increase the probability that the soil immediately around a cable may lose so much of its moisture that it dries out to a significantly higher value of thermal resistivity than that corresponding to its normal site condition. The reduction in permissible current-carrying capacity of a cable, necessary to avoid overheating, can be significant.

Scope: This part of IEC 60853 gives a method for calculating the cyclic rating factor, for cables of all voltages, where partial drying out of the surrounding soil is anticipated. The method is based on one of the three methods published in a CIGRE1 document. The method is applicable to any type of cable, but it is recommended that it should be applied only to installations of one multi-core cable or to three single-core cables or to groups of circuits where the intercircuit spacing is sufficient to permit free vertical movement of soil moisture between the zones of dry soil associated with each circuit. This standard does not preclude the use of other methods of calculation where full details of the load cycle are not known. The method assumes that the entire region surrounding a cable or cables has uniform thermal characteristics prior to drying out; the only non-uniformity being that caused by drying. As a consequence the method should not be applied, without further consideration, to installations where special backfills, having properties different from the site soil, are used.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope