IEC 60884-2-6 (REDLINE + STANDARD)-2025 PDF

IEC 60884-2-6 (REDLINE + STANDARD)-2025 PDF

Plugs and socket-outlets for household and similar purposes-Part 2-6: Particular requirements for switched socket-outlets with interlock for fixed electrical installations

$123.58 $247.16 -50%
Product Code: IEC 60884-2-6 (REDLINE + STANDARD)
Stock In Stock
Edition: 2.0
Published: 02/2025
Number of Pages: 40
File Size: 1 file

Available Options

Product Description

Plugs and socket-outlets for household and similar purposes – Part 2-6: Particular requirements for switched socket-outlets with interlock for fixed electrical installations

Scope: Replace IEC 60884-1:2022, Clause 1 with the following: This part of IEC 60884 applies to switched socket-outlets with interlock for AC only, for fixed electrical installations, with or without earthing contact, with rated voltage above 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors. Switched socket-outlets with interlock according to this document consist of a combination of socket-outlets according to IEC 60884-1, interlocked with a switch according to IEC 60669-1 and/or IEC 60669-2-1 supplied as a complete unit accessory. The rated current is limited to 16 A maximum for fixed accessories provided with screwless terminals. This document does not cover requirements for flush mounting boxes. However, it covers those requirements for surface-type mounting boxes which are necessary for the tests on socket-outlets. NOTE 1 General requirements for mounting boxes are covered by IEC 60670. NOTE 2 Interlocked socket-outlets incorporating devices according to IEC 60898, IEC 61008 and IEC 61009 are not covered by this document. This document may can be used as a guide for the requirements and tests of these accessories where relevant. This document does not apply to interlocked socket-outlets for industrial purposes; interlocked socket-outlets for EV; interlocked socket-outlets for SELV. Accessories complying with this standard are suitable for use at an ambient temperature not normally exceeding 25 °C, but occasionally reaching 35 °C. Plugs and socket-outlets complying with this document are suitable for use at ambient temperatures not normally exceeding +40 °C, but their average temperature over a period of 24 h does not exceed +35 °C, with a lower limit of the ambient air temperature of −5 °C.

Contents:

  • FOREWORD
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60884-2-6 (REDLINE + STANDARD)-2025 PDF

IEC 60884-2-6 (REDLINE + STANDARD)-2025 PDF

$123.58 $247.16