Live working – Conductive clothing
Introduction: This document provides specifications for protective conductive clothing currently being used without incident in live work by qualified electrical workers throughout the world. The adequacy of this clothing is established by its screening efficiency and the electrical resistance of material and component parts of the conductive clothing. Based on resistance measurements carried out by manufacturers and utilities of used clothing being successfully worn in the field, differences of up to 1 000 fold have been reported. The whole set-up and preparation work in very high voltage is made to limit the power of electric arcs during work activities. When, in the preparation phase of the work, the risk assessment leads to a high probability that there may be electric arcs, due to the short distances or unsuitable equipment insulation, the work is not done. This approach is dictated by the fact that the electric arcs produced by high-voltage installations have very significant thermal and electrical effects, which are hardly attenuated by protective clothing worn by operators. If protection against electric arc value is required by agreements between customer and manufacturer, it is possible to perform tests on the fabric and/or on the garment complete with accessories using the reference standards already published on this topic by IEC TC 78. This document has been prepared according to the requirements of IEC 61477, where applicable. The bibliography provides a list of papers of int
Scope: This document is applicable to conductive clothing, worn during live working (especially bare- hand working) on AC and DC electrical installations, to provide electrical continuity between all parts of the clothing and a reduction of electric field inside the clothing. This document is applicable to conductive clothing assembled from a conductive garment (jackets and trousers or coveralls forming a one-piece garment) and from conductive component parts (gloves, hoods or helmets, shoes or boots, overshoe socks and socks) in electrical systems with nominal voltage up to 1 000 kV AC and up to ±800 kV DC. This document does not indicate values of protection from the effects of the electric arc, because any value indicated would not guarantee the necessary protection from the effects of electric arcs, or the operator would need to wear very heavy and rigid conductive clothing, which would not allow the execution of the work in safety. The products designed and manufactured according to this document contribute to the safety of the users provided they are used by persons trained for the work, in accordance with the live working methods and the instructions for use.
Contents:
- FOREWORD
- INTRODUCTION
- Scope