Low-voltage switchgear and controlgear -Part 9-1: Active arc-fault mitigation systems - Arc quenching devices
Introduction: The effects of arc-faults inside an enclosure are more and more taken into consideration, both from user safety and time-to-repair points of view. Protection against the effects of internal arc-faults can be achieved through passive components (containment) or through active components, also known as "active arc-fault mitigation systems". Active arc-fault mitigation systems generally use internal arc-fault control devices (IACDs), based on the effects of the arc (light, pressure, current or voltage harmonics, etc.), and an actuator to eliminate the arc-fault. This actuator can be an upstream circuit-breaker, which is tripped to interrupt the fault current, or an arc quenching device that will transfer the fault to a dedicated low-impedance circuit, before the short-circuit current is interrupted by the upstream short-circuit protective device (SCPD). The purpose of this document is to set the requirements for arc quenching devices, so that the necessary safety is ensured and their performance can be fairly assessed. Special requirements for environmental withstand (e.g. ambient temperature, damp heat, shock, vibrations) are included, considering the high impact of a malfunction, either unwanted operation (creation of a short-circuit) or failure to operate. Requirements for internal arc-fault control devices are under development and will be published as IEC 60947-9-21. Requirements for integration of internal arc-fault mitigation systems in power switchgear and controlgear as
Scope: This part of IEC 60947 covers low-voltage arc quenching devices, hereinafter referred to as AQDs, which are intended to eliminate arc-faults in low-voltage assemblies (typically low- voltage switchgear and controlgear assemblies in accordance with the IEC 61439 series), by creating a lower impedance current path, to cause the arcing current to transfer to the new current path. This new current path is maintained until a short-circuit protection device (SCPD) interrupts the short-circuit current. AQDs are installed in low-voltage assemblies, connected to the main circuit, preferably as close as possible to all primary power sources. Their rated voltage does not exceed 1 000 V AC or 1 500 V DC. This document does not cover: sensors intended to detect arc-faults; devices intended to trigger the functioning of the arc quenching device; devices intended to interrupt arc-fault current; special requirements for AQDs for use in explosive atmospheres (e.g. ATEX).
Contents:
- FOREWORD
- INTRODUCTION
- Scope