Medical electrical equipment – Medical electron accelerators – Functional performance characteristics
Introduction: Standards containing safety requirements for medical ELECTRON ACCELERATORS have been published by the IEC, details of which will be found in Clause 2. The present standard specifies methods of testing and methods of disclosure of functional performance of medical ELECTRON ACCELERATORS intended for RADIOTHERAPY. It permits a direct comparison between the performance data of equipment of different MANUFACTURERS. Since this standard does not contain safety requirements, it has not been numbered in the IEC 60601 publication series. It describes aspects of functional performance of medical ELECTRON ACCELERATORS and the way in which they should be presented. It also includes test methods and conditions suitable for TYPE TESTS. These test methods are suggested test methods and alternative methods may be equally appropriate, but the specified functional performance characteristics of medical ELECTRON ACCELERATORS shall be related to these test methods and conditions. Tests specified in this standard are not necessarily appropriate for ensuring that any individual medical ELECTRON ACCELERATOR conforms to the declared functional performance during the course of its working lifetime. Guidance on the values which may be expected is given in the technical report, IEC 60977. This International Standard was first published in 1989. With the rapidly increasing use of medical ELECTRON ACCELERATORS equipped with multi-element BEAM LIMITING DEVICES (BLDs), amendments to both this standard and t
Scope: This International Standard applies to medical ELECTRON ACCELERATORS when used, for therapy purposes, in human medical practice. This standard applies to medical ELECTRON ACCELERATORS which deliver a RADIATION BEAM of either X-RADIATION or ELECTRON RADIATION with NOMINAL ENERGIES in the range 1 MeV to 50 MeV at maximum ABSORBED DOSE RATES between 0,001 Gy s–1 and 1 Gy s–1 at 1 m from the RADIATION SOURCE and at NORMAL TREATMENT DISTANCES between 50 cm and 200 cm from the RADIATION SOURCE. The present standard describes measurements and test procedures to be performed by the MANUFACTURER at the design and construction stage of a medical ELECTRON ACCELERATOR but does not specify ACCEPTANCE TESTS to be performed after installation at the purchaser's site. The accompanying report, IEC 60977, however, does suggest that many of the test procedures are appropriate for ACCEPTANCE TESTS. The measurement conditions described in the present standard differ from those previously in use. This applies particularly to the PHANTOM position for measurements and the measurement of distances from the ISOCENTRE. These new conditions should be substituted for and not be added to previous methods. This standard specifies test procedures for the determination and disclosure of functional performance characteristics, knowledge of which is deemed necessary for proper application and use of a medical ELECTRON ACCELERATOR and which are to be declared in the ACCOMPANYING DOCUMENTS together with the greatest deviation or variation to be expected under specific conditions in NORMAL USE. A format for presentation of functional performance values is given in Annex A. It is recognized that inaccuracies in the test methods must be allowed for when assessing performance. However, it was not felt to be advisable to combine the errors into an overall performance tolerance but to keep them separate in the expectation that more accurate test methods will be evolved. It is not intended that this standard should in any way inhibit the future development of new designs of equipment which may have operating modes and parameters different from those described herein, provided that such equipment achieves
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 5.10 Presentation
- 5.11 Dimensions, clearances, within the RADIATION HEAD, and in the region
- 5.12 IMRT