IEC 61000-3-2 (REDLINE + STANDARD)-2018 PDF

IEC 61000-3-2 (REDLINE + STANDARD)-2018 PDF

Electromagnetic compatibility (EMC)-Part 3-2: Limits-Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)

$278.68 $557.36 -50%
Product Code: IEC 61000-3-2 (REDLINE + STANDARD)
Stock In Stock
Edition: 5.0
Published: 01/2018
Number of Pages: 120
File Size: 1 file

Available Options

Product Description

Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)

Introduction: IEC 61000 is published in separate parts, according to the following structure: Part 1: General General considerations (introduction, fundamental principles) Definitions, terminology Part 2: Environment Description levels Classification of the environment Compatibility levels Part 3: Limits Emission limits Immunity limits (in so far as they do not fall under the responsibility of the product committees) Part 4: Testing and measurement techniques Measurement techniques Testing techniques Part 5: Installation and mitigation guidelines Installation guidelines Mitigation methods and devices Part 6: Generic standards Part 9: Miscellaneous Each part is further subdivided into sections which are to be published either as international standards, technical specifications, or as technical reports. These standards and reports will be published in chronological order and numbered accordingly (for example, 61000-6-1). This part is an international standard which gives emission limits for harmonic currents from equipment having an input current up to and including 16 A per phase. This part is a Product Family Standard. Each part is further subdivided into several parts, published either as international standards or as technical specifications or technical reports, some of which have already been published as sections. Others will be published with the part number followed by a dash and a second number identifying the subdivision (example: IEC 61000-6-1).

Scope: This part of IEC 61000 deals with the limitation of harmonic currents injected into the public supply system. It specifies limits of harmonic components of the input current which may can be produced by equipment tested under specified conditions. Harmonic components are measured according to Annexes A and B. This part of IEC 61000 is applicable to electrical and electronic equipment having an rated input current up to and including 16 A per phase, and intended to be connected to public low-voltage distribution systems. Arc welding equipment which is not professional equipment, with a rated input current up to and including 16 A per phase, is included in this document. Arc welding equipment intended for professional use, as specified in IEC 60974-1, is excluded from this document and may can be subject to installation restrictions as indicated in IEC/TR 61000-3-4 or IEC 61000-3-12. The tests according to this document are type tests. Test conditions for particular equipment are given in Annex C. For systems with nominal voltages less than but not equal to 220 V (line-to-neutral), the limits have not yet been considered. NOTE The words apparatus, appliance, device and equipment are used throughout this document. They have the same meaning for the purposes of this document.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 61000-3-2 (REDLINE + STANDARD)-2018 PDF

IEC 61000-3-2 (REDLINE + STANDARD)-2018 PDF

$278.68 $557.36