Electromagnetic compatibility (EMC) Part 4-33: Testing and measurement techniques Measurement methods for high-power transient parameters
Introduction: IEC 61000 is published in separate parts according to the following structure: Part 1: General General considerations (introduction, fundamental principles) Definitions, terminology Part 2: Environment Description of the environment Classification of the environment Compatibility levels Part 3: Limits Emission limits Immunity limits (in so far as they do not fall under the responsibility of the product committees) Part 4: Testing and measurement techniques Measurement techniques Testing techniques Part 5: Installation and mitigation guidelines Installation guidelines Mitigation methods and devices Part 6: Generic standards Part 9: Miscellaneous Each part is further subdivided into several parts and published either as International Standards or as technical specifications or technical reports, some of which have already been published as sections. Others will be published with the part number followed by a dash and a second number identifying the subdivision (example: 61000-6-1).
Scope: This part of IEC 61000 provides a basic description of the methods and means (e.g., instrumentation) for measuring responses arising from high-power transient electromagnetic parameters. These responses can include: the electric (E) and/or magnetic (H) fields (e.g., incident fields or incident plus scattered fields within a system under test); the current I (e.g., induced by a transient field or within a system under test); the voltage V (e.g., induced by a transient field or within a system under test); the charge Q induced on a cable or other conductor. NOTE The charge Q on the conductor is a fundamental quantity that can be defined at any frequency. The voltage V, however, is a defined (e.g., secondary) quantity, which is valid only at low frequencies. At high frequencies, the voltage cannot be defined as the line integral of the E-field, since this integral is path-dependent. Thus, for very fast rising pulses (having a large high-frequency spectral content) the use of the voltage as a measurement observable is not valid. In this case, the charge is the desired quantity to be measured. These measured quantities are generally complicated time-dependent waveforms, which can be described approximately by several scalar parameters, or “observables”. These parameters include: the peak amplitude of the response, the waveform rise-time, the waveform fall-time (or duration), the pulse width, and mathematically defined norms obtained from the waveform. This International Standard provides information on the measurement of these waveforms and on the mathematical determination of the characterizing parameters. It does not provide information on specific level requirements for testing.
Contents:
- FOREWORD
- INTRODUCTION
- Scope