Nuclear facilities – Instrumentation and control systems – Design, location and application criteria for installed area gamma radiation dose rate monitoring equipment for use during normal operation and anticipated operational occurrences
Introduction: a) Technical background, main issues and organisation of the standard This IEC standard specifically focuses on radiation monitoring systems used for normal operation and anticipated operational occurrences in nuclear facilities such as nuclear power plants. This document is intended for use by purchasers in developing specifications for their plant specific radiation monitoring systems and by manufacturers to identify needed product characteristics when developing systems for normal operation and anticipated operational occurrences. Some specific instrument characteristics such as measurement range, required energy response, and ambient environment requirements will depend upon the specific application. In such cases guidance is provided on determining the specific requirements, but specific requirements themselves are not stated. This document is intended to be used in conjunction with IEC 60532:2010. For area gamma radiation dose rate monitoring equipment for accident and post-accident conditions refer to IEC 60951-1 and IEC 60951-3 (not within the scope of this document). b) Situation of the current standard in the structure of the IEC SC 45A standard series IEC 61031 is at the third level in the hierarchy of SC 45A standards. This document provides requirements for equipment for area radiation monitoring in normal conditions in conjunction with IEC 60532. Other standards developed by SC 45A and SC 45B provide guidance on instruments used for monitoring radiation as part
Scope: Sampling Calibration Accident and post accident conditions Normal conditions Radioactive noble gas off-line monitoring ISO 2889 ISO 4037-1, ISO 4037-3 IEC 60951-1, IEC 60951-2 N/A IEC 62302, IEC 60761-1, IEC 60761-3 Radioactive aerosol off- line monitoring ISO 2889 ISO 4037-1, ISO 4037-3 IEC 60951-1, IEC 60951-2 N/A IEC 60761-1, IEC 60761-2 Radioactive iodine off- line monitoring ISO 2889 ISO 4037-1, ISO 4037-3 IEC 60951-1, IEC 60951-2 N/A IEC 60761-1, IEC 60761-4 Liquid off-line monitoring N/A N/A N/A N/A IEC 60861 Tritium off-line monitoring N/A N/A N/A N/A IEC 62303 / IEC 60761-1, IEC 60761-5 On-line or in-line monitoring N/A ISO 4037-1, ISO 4037-3 IEC 60951-1, IEC 60951-4 IEC 60768 N/A Area monitoring N/A ISO 4037-1, ISO 4037-3 IEC 60951-1, IEC 60951-3 IEC 61031 IEC 60532 Centralized system N/A N/A IEC 61504, IEC 60960 IEC 61559-1 Classification/basic requirements N/A N/A IEC 61513, IEC 60880, IEC 60987, IEC 61226, IEC 62138, IEC 62566, IEC 62645, IEC 61250 IEC 61500, IEC 61504 N/A Qualification N/A N/A IEC 60980, IEC 62003, IEC/IEEE 60780-323 IEC 62706 For more details on the structure of the IEC SC 45A standard series, see item d) of this introduction. c) Recommendations and limitations regarding the application of this Standard It is important to note that this document establishes no additional functional requirements for safety systems. d) Description of the structure of the IEC SC 45A standard series and relationships with other IEC documents and other bodies’ documents (IAEA, ISO) The top-level documents of the IEC SC 45A standard series are IEC 61513 and IEC 63046. IEC 61513 provides general requirements for I&C systems and equipment that are used to perform functions important to safety in NPPs. IEC 63046 provides general requirements for electrical power systems of NPPs; it covers power supply systems including the supply systems of the I&C systems. IEC 61513 and IEC 63046 are to be considered in conjunction and at the same level. IEC 61513 and IEC 63046 structure the IEC SC 45A standard series and shape a complete framework establishing general requirements for instrumentation, control and electrical systems for nuclear power plants. – 8 – IEC 610
Contents:
- FOREWORD
- INTRODUCTION
- Scope