Single-capped fluorescent lamps – Safety specifications
Introduction: For the ease of measurement, a new location for measuring the maximum cap temperature and maximum cap temperature rise has been introduced with this third edition of this standard, resulting in new temperature values. However, the design of lampholders is based on the traditional measurement location. Therefore, a new Annex I has been introduced, providing the previous methods and values for those lamp types and kinds of lamp operation, which have been already covered in the previous edition of this standard. For lamps, which are operated by means of an electronic ballast however, also a new measurement method and temperature limits are given. Special attention has been given to the requirements related to high frequency operation, not covered in the previous edition. The standards IEC 62471,and IEC/TR 62471-2, contain horizontal requirements available that need to be introduced into product standards, e.g. to IEC 61199. The horizontal requirements are transformed into requirements for single-capped fluorescent lamps. The lamps within the scope of this standard are general lighting service (GLS) lamps according to the definition 3.11 of IEC 62471;2006. "...lamps intended for lighting spaces that are typically occupied or viewed by people..." According to Clause 6 of IEC 62471:2006, radiation of GLS lamps is measured at a distance equivalent to 500 lx. Measured at the 500 lx distance, GLS lamps will not exceed risk group 1 for blue light hazard and risk group 0 for IR radiatio
Scope: This International Standard specifies the safety requirements for single-capped fluorescent lamps for general lighting purposes of all groups having caps according to Table 1. It also specifies the method a manufacturer should use to show compliance with the requirements of this standard on the basis of whole production appraisal in association with his test records on finished products. This method can also be applied for certification purposes. Details of a batch test procedure which can be used to make limited assessment of batches are also given in this standard. This part of the standard covers photobiological safety according to IEC 62471 and IEC/TR 62471-2. Blue light and infrared hazards are below the level which requires marking. NOTE Compliance with this standard concerns only safety criteria and does not take into account the performance of single-capped fluorescent lamps for general lighting purposes with respect to luminous flux, colour, starting and operational characteristics. For this information, readers are referred to IEC 60901. Table 1 – Sheet references of IEC 60061 Sheet numbers Cap type IEC 60061-1 Lamp caps IEC 60061-3 Cap gauges 2G7 7004-102 7006-102 2GX7 7004-103 7006-102 2G8 7004-141 7006-141, 141H, 141J, 141K GR8 7004-68 7006-68A, 68B, 68E G10q 7004-54 7006-79 GR10q 7004-77 7006-77A, 68B, 68E GU10q 7004-123 7006-123, 123A GX10q 7004-84 7006-79, 84, 84A and 84B GY10q 7004-85 7006-79, 85 and 85A GZ10q 7004-124 7006-79 2G10 7004-118 7006-118 2G11 7004-82 7006-82 2GX11-1 7004-82A 7006-82F, 82G, 82H 2GX13 7004-125 7006-125A, 125B G23 7004-69 7006-69 GX23 7004-86 7006-86 G24, GX24 7004-78 7006-78 GZ24q GX32 7004-87 7006-87 * to be developed. IEC 61199:2011 – 9 – +AMD1:2012+AMD2:2014 CSV © IEC 2014 It may be expected that lamps which comply with this standard will operate safely at supply voltages between 90 % and 110 % of rated supply voltage of the used ballast and when operated with a ballast complying with IEC 61347-2-3 or IEC 61347-2-8 with a starting device complying with IEC 60155 (if applicable) and in a luminaire complying with IEC 60598-1.
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 4.10 Radio interference suppression capacitors
- 4.10.1 General
- 4.10.2 Moisture resistance
- 4.10.3 Resistance to flame and ignition
- 4.11 UV radiation
- 4.12 Information for luminaire design
- 4.13 Information for ballast design
- 4.14 Information for lampholder design