Evaluation and Routine Testing in Medical Imaging Departments - Part 2-9: Constancy Tests - Equipment for Indirect Radioscopy and Indirect Radiography

$100.88 $201.76 -50%
Product Code: IEC 61223-2-9
Stock In Stock
Edition: 1.0
Published: 09/1999
Number of Pages: 28
File Size: 1 file, 89 Bytes

Available Options

Product Description

Evaluation and Routine Testing in Medical Imaging Departments - Part 2-9: Constancy Tests - Equipment for Indirect Radioscopy and Indirect Radiography

Scope: This part of IEC 61223 applies to those components of X-RAY EQUIPMENT which a) generate, influence the propagation of, and detect X-RADIATION, and b) process, present and store diagnostic X-ray images in RADIOLOGICAL INSTALLATIONS with diagnostic X-ray systems for INDIRECT RADIOSCOPY and INDIRECT RADIOGRAPHY which use X- RAY IMAGE INTENSIFIERS in conjunction with analogue and/or digital storage systems: closed-circuit television display systems: cut film cameras cine cameras. This standard is a part of a series of Particular Publications (international standards and technical reports) which define methods of testing the constancy of operation of various sub- systems of diagnostic X-RAY EQUIPMENT. This standard gives methods of tests for the constancy of properties of diagnostic X-RAY EQUIPMENT as described in IEC 61223-1 (see clause 2). This part of IEC 61223 is designed to be applicable to equipment for indirect radioscopy and indirect radiography without digital imaging devices. 1.2 Object This standard defines the essential parameters which describe or affect the performance of the above components of X-RAY EQUIPMENT, and methods of checking that variations in measured quantities related to those parameters are within acceptable limits, in order to maintain adequate standards of imaging whilst reducing unnecessary IRRADIATION of the PATIENT. These methods are based upon assessment of radiological information using appropriate TEST DEVICES. The purpose of the methods is to establish a reference level of performance when such equipment is accepted; to detect or verify any significant variation in functional parameters which may then require corrective actions. – 6 – 61223-2-9 © IEC:1999(E) Because RADIOLOGICAL INSTALLATIONS differ widely from each other, it is not possible in this standard to specify target values and tolerances for the parameters which would be generally applicable as criteria of acceptable performance. Guidance is given, however, as to the degree of variation in single measurements which might require appropriate action. This standard is not intended to deal with aspects of mechanical and electrical safety; checks of the effectiveness of the

Contents:

  • FOREWORD
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 61223-2-9-1999 PDF

IEC 61223-2-9-1999 PDF

$100.88 $201.76