Electrical Apparatus for Use in the Presence of Combustible Dust - Part 2: Test Methods - Section 1: Methods for Determining the Minimum Ignition Temperatures of Dust First Edition
Introduction: This section of IEC 1241-2 describes methods for determining the minimum ignition temperature of dust which are: method A: Dust layer on a heated surface at a constant temperature (clause 4); method B: Dust cloud in a furnace at a constant temperature (clause 5). Method A determines the minimum ignition temperature of a dust layer on a prescribed heated surface. Method B determines the minimum ignition temperature of a dust cloud within a prescribed heated furnace. The test methods are of a general nature, and may be used for purposes of comparison, but in certain industrial situations further tests may be necessary. The methods for determining the minimum ignition temperatures are not suitable for use with recognized explosives, for example, gunpowder, dynamite, or mixtures of substances which may, under some circumstances, behave similarly. Where there is doubt, an indication of the existence of a hazard due to explosive pro- perties may be obtained by testing a very small quantity of the dust on a surface at 400 °C or higher, located remotely from the operator.
Scope: This section of IEC 1241-2 specifies two test methods for determining the minimum ignition temperatures of dust. The methods are not suitable for use with substances having explosive properties. Method A (clause 4) is applicable to the determination of the minimum temperature of a prescribed hot su rface which will result in the decomposition and/or ignition of a layer of dust of a specified thickness deposited on it. The method is particularly relevant to industrial equipment with which dust is present on hot su rfaces in thin layers exposed to the atmosphere. Method B (clause 5) is applicable to the determination of the minimum temperature of a prescribed hot su rface which will result in the ignition of a cloud of a given sample of dust or other particulate solid. The test is intended to be carried out as a complementary test after determining the minimum ignition temperature of a dust layer by method A of this standard. NOTES concerning method B 1 Because the method of operation of the furnace gives short residence times for dust particles within it, this method of test is applicable to industrial equipment where dust is present as a cloud for a short time. This method of test is of small scale and the results are not necessarily representative of all industrial conditions. 2 The method is not applicable to dusts which may, over a longer period of time than provided for in the test method, produce from deposits gases generated during pyrolysis or smouldering.
Contents:
- FOREWORD
- INTRODUCTION
- 1 Scope
- 2 Normative references
- 4 Method A: Dust layer on a heated surface at a constant temperature
- 4.1 Preparation of dust sample
- 4.2 Test apparatus
- 4.3 Procedure
- 4.4 Test acceptance criteria
- 4.5 Reporting of results
- 4.6 Application of results
- 5 Method B: Dust cloud in a furnace at a constant temperature
- 5.1 Preparation of dust sample
- 5.2 Test apparatus
- 5.3 Procedure
- 5.4 Criterion of ignition
- 5.5 Minimum ignition temperature of a dust cloud
- 5.6 Reporting of results