Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers - Part 6: Determination of the contrast ratio and veiling glare index

$50.44 $100.88 -50%
Product Code: IEC 61262-6
Stock In Stock
Edition: 1.0
Published: 07/1994
Number of Pages: 30
File Size: 1 file, 993 Bytes

Available Options

Product Description

Medical electrical equipment - Characteristics of electro-optical X-ray image intensifiers - Part 6: Determination of the contrast ratio and veiling glare index

Introduction: The CONTRAST RATIO (CR) and the VEILING GLARE INDEX (VGI), which is defined as the reciprocal of the CR, are measures of the spatial frequency response of an imaging system at low frequencies and, as such, complement the limiting spatial resolution, which is a measure of a system's high-frequency response. Although the CR and the VGI can, in principle, be estimated from the MODULATION TRANSFER FUNCTION, it is simpler to measure them directly. The contrast represented by the difference in X-ray fluence between an object and its surroundings can be diminished by the imaging device. Generally, this loss of contrast is due to scattering of the image-carrying quanta away from the ideal paths. The radiance in the image due to imaging the scattered quanta is called "veiling glare." Processes that contribute to veiling glare include the scattering Of X- RADIATION at the ELECTRO-OPTICAL X-RAY IMAGE INTENSIFIER input and the scattering of light at its output. For an ELECTRO-OPTICAL X-RAY IMAGE INTENSIFIER, the CR is the ratio of the luminance at the CENTRE OF THE OUTPUT IMAGE with no TEST DEVICE in the X-RAY BEAM t0 the luminance at the CENTRE OF THE OUTPUT IMAGE with a CR TEST DEVICE in the X -RAY BEAM. While the CR is unbounded, ranging from 1 to infinity, the VGI is bounded between 0 and 1.

Scope: This International Standard applies to ELECTRO-OPTICAL X-RAY IMAGE INTENSIFIERS for medical use, as components of diagnostic X-RAY EQUIPMENT. This International Standard describes a method of determining the CONTRAST RATIO (CR) and the VEILING GLARE INDEX (VGI) of ELECTRO-OPTICAL X-RAY IMAGE INTENSIFIERS.

Contents:

  • FOREWORD
  • INTRODUCTION
  • 1 Scope
  • 2 Normative reference
  • 3 Terminology
  • 4 Requirements
  • 4.2 X-RAY IMAGE INTENSIFIER Operating conditions
  • 4.4 TEST DEVICE
  • 4.5 Measurement equipment
  • 5 Determination of the CONTRAST RATIO and the VEILING GLARE INDEX
  • 5.2 Measurement
  • 5.3 Corrections
  • 6 Presentation of the CONTRAST RATIO and the VEILING GLARE INDEX
  • 7 Statement of compliance