IEC 61326-3-2 (REDLINE + STANDARD)-2017 PDF

IEC 61326-3-2 (REDLINE + STANDARD)-2017 PDF

Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Industrial applications with specified electromagnetic environment

$278.68 $557.36 -50%
Product Code: IEC 61326-3-2 (REDLINE + STANDARD)
Stock In Stock
Edition: 2.0
Published: 05/2017
Number of Pages: 122
File Size: 1 file, 1.9 MB

Available Options

Product Description

Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 3-2: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) - Industrial applications with specified electromagnetic environment

Introduction: Functional safety is that part of the overall safety relating to the equipment under control (EUC) and the EUC control system which depends on the correct functioning of the electrical safety-related systems. To achieve this, all items of equipment of the safety-related system which are involved in the performance of the safety functions must behave in a specified manner under all relevant conditions. The IEC basic safety publication for functional safety of electrical/electronic/programmable electronic safety-related systems is IEC 61508. It sets the overall requirements to achieve functional safety. Sufficient immunity to electromagnetic disturbances is one of those requirements. The concept of IEC 61508 distinguishes between the consideration of the application and the design of safety-related electrical and electronic systems. The interface between both is The overall safety requirements specification (SRS). It specifies all relevant requirements of the intended application, as follows. a) definition of the safety functions, based on a risk assessment of the intended application (which functions are intended to reduce risk); b) appropriate safety integrated integrity level (SIL) for each safety function based on a risk assessment of the intended application; c) definition of the environment in which the system is intended to work including the electromagnetic environment as required by IEC 61508-2. The requirements for each safety function are then specified in one or mor

Scope: This part of IEC 61326 covers all equipment within the scope of IEC 61326-1 applies to this part of IEC 61326, but is limited to systems and equipment for industrial applications within a specified electromagnetic environment and intended to perform safety functions as defined in IEC 61508 with SIL 1-3. The electromagnetic environments encompassed by this product family standard are industrial, both indoor and outdoor, as they can be found in industrial applications with an electromagnetic environment having specified characteristics (for example, process industry), and based on the requirements of the process industry, specifically chemical/petrochemical/pharmaceutical manufacturing plants using the mitigation measures given in Annex C. The difference between the electromagnetic environment covered by this document compared to the general industrial environment (see IEC 61326-3-1) is due to the mitigation measures employed against electromagnetic phenomena leading to a specified electromagnetic environment with test values that have been proven in practice. The environment of industrial application with a specified electromagnetic environment typically includes the following characteristics: industrial area with limited access; limited use of mobile transmitters; dedicated cables for power supply and control, signal or communication lines; separation between power supply and control, signal or communication cables; factory building mostly consisting of metal construction; overvoltage/lightning protection by appropriate measures (for example, metal construction of the building or use of protection devices); pipe heating systems driven by AC main power may be present; no high-voltage substation close to sensitive areas; presence of CISPR 11 Group 2 ISM equipment using ISM frequencies only with low power; competent staff; periodical maintenance of equipment and systems; mounting and installation guidelines for equipment and systems. A more detailed description of the above-mentioned typical characteristics is given in Annex B. Equipment and systems considered as “proven-in-use” according to IEC 61508 or “prior use” according to IEC 61511 are excluded from the scop

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 61326-3-2 (REDLINE + STANDARD)-2017 PDF

IEC 61326-3-2 (REDLINE + STANDARD)-2017 PDF

$278.68 $557.36