Controlgear for electric light sources – Safety – Part 2-10: Particular requirements – Electronic controlgear for high-frequency operation of tubular cold-cathode discharge lamps (neon tubes)
Introduction: The technical requirements in this document compared to IEC 61347-2-10:2000 and IEC 61347-2-10:2000/AMD1:2008 are essentially unchanged. Nevertheless, a new edition of this document could not be avoided, as without the introduction of dated references to IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017, the fourth edition of IEC 61347-1:—1 would have been implicitly applicable due to the undated nature of the references to IEC 61347-1 in IEC 61347-2-10:2000 and IEC 61347-2-10:2000/AMD1:2008. This document, in referring to any of the clauses of IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017, specifies the extent to which such a clause is applicable. Additional requirements are also included, as necessary. In order to check the safety of controlgear, it is necessary to check their performance. However, since no standardization of the characteristics of neon tubes exists, reference loads are specified in this document to ensure reproducible test results. ___________ Fourth edition under preparation. Stage at the time of publication IEC FDIS 61347-1:2024.
Scope: This part of IEC 61347 specifies safety requirements for electronic controlgear for high- frequency operation of tubular cold-cathode discharge lamps used in signs and luminous discharge tube installations and operating with an output voltage exceeding 1 000 V but not exceeding 10 000 V for direct connection to DC or AC supply voltages not exceeding 1 000 V (at 50 Hz or 60 Hz in case of alternating current). NOTE 1 Historically, such types of controlgear were referred to as invertors or convertors. NOTE 2 In Japan, the voltage limit for the application of this document is set to 15 000 V. This document applies for controlgear of type A and controlgear of type B, which are specified as follows: Type A: controlgear operating within the frequency range 20 kHz to 50 kHz, and having an output voltage not exceeding 5 000 V peak between terminals, with a maximum output current limited to 35 mA (RMS) and 50 mA (peak value) and a supply voltage not exceeding 250 V. NOTE 3 The output current of a type A unit can be considered as not presenting an electric shock hazard due to the limits on the current and frequency range. NOTE 4 In Japan, the output voltage of 15 000 V is acceptable. Type B: controlgear operating within the frequency range 10 kHz to 100 kHz and having a no-load output voltage not exceeding 10 000 V between terminals or not exceeding 5 000 V to earth, with a maximum output current limited to 200 mA (RMS) and 400 mA (peak value). NOTE 5 In Japan, a type B controlgear providing an output current exceeding 50 mA is not acceptable.
Contents:
- FOREWORD
- INTRODUCTION
- Scope