Controlgear for electric light sources – Safety – Part 2-10: Particular requirements – Electronic controlgear for high-frequency operation of tubular cold-cathode discharge lamps (neon tubes)
Introduction: This part of IEC 61347, and the parts which make up IEC 61347-2, in referring to any of the clauses of IEC 61347-1, specify the extent to which such a clause is applicable and the order in which the tests are to be performed; they also include additional requirements, as necessary. All parts which make up IEC 61347-2 are self-contained and, therefore, do not include references to each other. Where the requirements of any of the clauses of IEC 61347-1 are referred to in this standard by the phrase ”The requirements of clause n of IEC 61347-1 apply”, this phrase is interpreted as meaning that all requirements of the clause in question of part 1 apply, except any which are clearly inapplicable to the specific type of lamp controlgear covered by this particular part of IEC 61347-2. The technical requirements in this document compared to IEC 61347-2-10:2000 and IEC 61347-2-10:2000/AMD1:2008 are essentially unchanged. Nevertheless, a new edition of this document could not be avoided, as without the introduction of dated references to IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017, the fourth edition of IEC 61347-1:—1 would have been implicitly applicable due to the undated nature of the references to IEC 61347-1 in IEC 61347-2-10:2000 and IEC 61347-2-10:2000/AMD1:2008. This document, in referring to any of the clauses of IEC 61347-1:2015 and IEC 61347-1:2015/AMD1:2017, specifies the extent to which such a clause is applicable. Additional requirements are also included, as necessar
Scope: This part of IEC 61347 specifies particular safety requirements for electronic invertors and convertors controlgear for high-frequency operation of tubular cold-cathode discharge lamps used in signs and luminous discharge tube installations and operating with an output voltage exceeding 1 000 V but not exceeding 10 000 V for direct connection to DC or AC supply voltages not exceeding 1 000 V (at 50 Hz or 60 Hz or 1 000 V d.c in case of alternating current). NOTE 1 Historically, such types of controlgear were referred to as invertors or convertors. NOTE 12 In Japan, the output voltage limit for the application of this document is set to 15 000 V is acceptable. The requirements for two types of invertors and convertors, types A and B, are specified as follows: Type A unit: an invertor or convertor operating within the frequency range 20 kHz to 50 kHz, and having an output voltage (between terminals) not exceeding 5 000 V peak, a maximum output current limited to 35 mA (r.m.s.) and 50 mA (peak value). The supply voltage does not exceed 250 V at 50 Hz or 60 Hz or 250 V d.c. NOTE 2 The output current of a type A unit may be considered as not presenting an electric shock hazard due to the limits on the current and frequency range. NOTE 3 In Japan, the output voltage of 15 000 V is acceptable. Type B unit: an invertor or convertor having a no-load output voltage not exceeding 5 000 V to earth or 10 000 V between terminals, operating within the frequency range 10 kHz to 100 kHz with a maximum output current limited to 200 mA (r.m.s.) and 400 mA (peak value). NOTE 4 Type B units require additional protection in the output circuit. NOTE 5 In Japan, a type B unit exceeding 50 mA and/or the secondary grounded is not acceptable. In order to check the safety of invertors or convertors, it is necessary to check their performance. However, since no standardization of the characteristics of neon tubes exists, reference loads are specified in this standard to ensure reproducible test results. The rated maximum operating temperature of the winding, tw, is not applicable to this standard. This document applies for controlgear of type A and controlgear of type B, which are specified
Contents:
- FOREWORD
- INTRODUCTION
- Scope