IEC 61472-2013 PDF

IEC 61472-2013 PDF

Live working-Minimum approach distances for a.c. systems in the voltage range 72,5 kV to 800 kV-A method of calculation

$186.00 $371.99 -50%
Product Code: IEC 61472
Stock In Stock
Edition: 3.0
Published: 04/2013
Number of Pages: 94
File Size: 2 files, 1000 Bytes

Available Options

Product Description

Live working – Minimum approach distances for a.c. systems in the voltage range 72,5 kV to 800 kV – A method of calculation

Scope: This International Standard describes a method for calculating the minimum approach distances for live working, at maximum voltages between 72,5 kV and 800 kV. This standard addresses system overvoltages and the working air distances or tool insulation between parts and/or workers at different electric potentials. The required withstand voltage and minimum approach distances calculated by the method described in this standard are evaluated taking into consideration the following: workers are trained for, and skilled in, working in the live working zone; the anticipated overvoltages do not exceed the value selected for the determination of the required minimum approach distance; transient overvoltages are the determining overvoltages; tool insulation has no continuous film of moisture or measurable contamination present on the surface; no lightning is seen or heard within 10 km of the work site; allowance is made for the effect of conducting components of tools; the effect of altitude, insulators in the gap, etc, on the electric strength is taken into consideration. For conditions other than the above, the evaluation of the minimum approach distances may require specific data, derived by other calculation or obtained from additional laboratory investigations on the actual situation. Terms, definitions and symbols For the purpose of this document, the following terms, definitions and symbols apply. 2.1 Terms and definitions 2.1.1 damaged insulator insulator having any type of manufacturing defect or in-service deterioration which affects its insulating performance 2.1.2 electrical distance DU distance in air required to prevent a disruptive discharge between energized parts or between energized parts and earthed parts during live working [SOURCE: IEC 60050-651:–, 651-21-12] – 46 – 61472 © CEI:2013 AVANT-PROPOS .................................................................................................................. 48 Domaine d'application .................................................................................................... 50 Termes, définitions et symboles ....................................................................................

Contents:

  • FOREWORD
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 61472-2013 PDF

IEC 61472-2013 PDF

$186.00 $371.99