Nuclear Reactor Instrumentation - Wide Range Neutron Fluence Rate Meter - Mean Square Voltage Method

$163.93 $327.86 -50%
Product Code: IEC 61501
Stock In Stock
Edition: 1.0
Published: 11/1998
Number of Pages: 88
File Size: 1 file, 296 Bytes

Available Options

Product Description

Nuclear Reactor Instrumentation - Wide Range Neutron Fluence Rate Meter - Mean Square Voltage Method

Introduction: The response of a fission chamber to a neutron is to produce a pulse of electrical charge and by counting these pulses it is possible to measure the neutron fluence rate. At higher levels the rate of pulse generation increases to the point where pulses merge (a phenomenon known as "pulse pile-up") and the process of electronically counting the pulses becomes impracticable. An alternative approach to processing is to consider the piled-up pulses as a fluctuating d.c. signal. Using Campbell's theory it can be shown that the mean square of the signal amplitude, measured over a fixed bandwidth, is proportional to the initial pulse rate. At low fluence rate levels the use of this approach is limited to 103 to 104 fissions per second by background noise in the electronics and in the fission chamber. The limit at high fluence rate levels is in the range 1010 to 1011 fissions per second because of non linearity caused by space charge effects. This is the most common application of the MSV method. The use of the mean square voltage (MSV) measurement technique in combination with pulse counting permits the design of a system capable of measuring a neutron fluence rate over a range of more than 11 decades using a single fission chamber with appropriate corrections. It is also possible to use two different detectors.

Scope: This International Standard applies to instrument and measurement channels which generate a calculation of the mean square voltage (MSV) of a signal arising from a neutron detector, in order to extract from it information relating to the neutron fluence rate of a nuclear reactor. After calibration, this information can be used to derive the relative power and the time constant, for example expressed in terms of period, doubling time, decades per minute or percent per second. The method used to calculate the mean square voltage of the signal is also known as "fluctuation treatment" or "the Campbell method". Associated with other techniques of measurement, such as pulse rate counting or current measurement, the calculation of the mean square voltage allows the assembly of a series of wide range neutron fluence rate measurements for the simplification of nuclear instrumentation systems in the control of nuclear reactors. This standard describes the principles, the terminology, the characteristics, the requirements and the testing methods related to instrumentation and measurement of the neutron fluence rate using MSV techniques for nuclear reactor control. Typical examples of the application of the MSV techniques are given.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope
  • 10 Characteristics and test methods for preamplifiers
  • 10.1 Characteristics of the preamplifier
  • 10.2 Test methods for the preamplifier
  • 11 Characteristics and test methods for quadratic amplifiers
  • 11.1 Characteristics of the quadratic amplifier
  • 11.2 Test methods for the quadratic amplifier
  • 12 Characteristics and test methods for logarithmic amplifiers
  • 12.1 Characteristics of the logarithmic amplifier
  • 12.2 Test methods for the logarithmic amplifier
  • 13 Characteristics and test methods for logarithmic summing amplifiers
  • 13.2 Test methods for the summing amplifier
  • 14 Characteristics and test methods for digital mean square processors (DMSP)
  • 14.1 Characteristics of the digital mean square processor
  • 14.2 Test methods for the DMSP