Radiation protection instrumentation - Measurement of personal dose equivalents for X, gamma, neutron and beta radiations - Active personal dosemeters
Introduction: This document applies to active, (direct reading or hybrid) personal dosemeters and monitors used for measuring personal dose equivalents Hp(10), Hp(3), and Hp(0,07), for X, gamma, neutron, and beta radiations. For personal dose equivalent Hp(10) and for X and gamma radiation, two minimum rated ranges for the photon energy are given. The first from 20 keV to 150 keV is for workplaces where low energy X-rays are used, e.g., in diagnostic medicine, the second from 80 keV to 1,25 MeV is for workplaces where high energy X-rays and/or gamma sources are used, e.g., in industry. For neutron radiation the minimum rated range of neutron energy is from 0,025 eV (thermal neutrons) to 10 MeV. The rated ranges can be extended to all energies covered by the respective standards for reference radiation fields. For personal dose equivalent Hp(3) and for X and gamma radiation, a minimum rated range for photon energy from 30 keV to 250 keV is given. For personal dose equivalent Hp(0,07) a range of 30 keV to 1250 keV or, for workplaces where low energy X-rays are used, 20 keV to 150 keV, is given. For beta radiation for both quantities, the minimal rated range is from 0,24 MeV to 0,8 MeV (mean beta particle energy). The rated ranges can be extended to all energies covered by the respective standards for reference radiation fields. In some applications, for example, at a nuclear reactor installation where 6 MeV photon radi- ation is present, measurement of personal dose equivalent (rate) Hp(10)
Scope: This document applies to personal dosemeters with the following characteristics: a) They are worn on the trunk, close to the eye, or on the extremities. b) They measure the personal dose equivalents Hp(10), Hp(3), and Hp(0,07), from external X and gamma, neutron (not for Hp(3)), and beta radiations, and may measure the respective personal dose equivalent rates for the same radiations (for alarming purposes). c) They have a digital indication. This indication may or may not be attached. d) They have alarm functions for the personal dose equivalents or personal dose equivalent rates except for hybrid dosemeters. For hybrid dosemeters an alarm function for the personal dose equivalents shall be implemented in the associated readout system. NOTE 1 When reference is made in this document to "dose", this is meant to indicate personal dose equivalent, unless otherwise stated. NOTE 2 When reference is made in this document to "dosemeter", this is meant to include all personal dosemeters, unless otherwise stated. NOTE 3 This document does not cover neutron dosemeters for the Hp(3) measurements up to now. This document specifies requirements for the dosemeter and, if supplied, for its associated readout system. Usually, a dosemeter is not able to measure all quantities given above. Thus, the dosemeter is only tested with regard to those quantities and types of radiation it is intended to be used for. Other types of radiation are considered as influence quantities which also may have requirements. This document specifies, for the dosemeters described above, general characteristics, general test procedures, radiation characteristics as well as electrical, mechanical, safety and envi- ronmental characteristics. The only requirements specified for associated readout systems are those which affect its accuracy of readout of the personal dose equivalent and alarm settings, and those which concern the influence of the reader on the dosemeter. This document does not cover special requirements for accident or emergency dosimetry, although the dosemeters may be used for this purpose. This document does not apply to dosemeters used for measurement of pulsed radiation, such as radiat
Contents:
- FOREWORD
- INTRODUCTION
- Scope