Connecting Devices - Devices for the Connection of Aluminium Conductors in Clamping Units of Any Material and Copper Conductors in Aluminium Bodied Clamping Units
Introduction: U.S. experience with screw-type terminations containing aluminium indicates that adequacy of terminations must be verified by a current-cycling test. This applies to connecting devices made of aluminium for use with copper or aluminium conductors, or non-aluminium connecting devices for use with aluminium conductors. These requirements were developed in conjunction with extensive use in the U.S. of aluminium conductors and aluminium bodied connecting devices and are contained in ANSI UL Standard 486E. Extensive investigations conducted by the manufacturers and UL over a period of some eight years and finalized in 1978 showed that temperature conditions become stable (asymptotic) before 500 cycles and consequently 500 test cycles were found to be sufficient. Since temperature measurements can be made easily and reliably, the test is based on temperature measurements. All the relevant connecting devices made by the major manufacturers in the U.S. comply with and carry the UL Listing since 1978. To facilitate the understanding of the test requirements in this standard, the following explanations have been developed. This standard covers connecting devices containing clamping units as separate entities or provided as an integral part of a product (see figure 1). Case A – A terminal is considered as a separate entity when submitted by the manufacturer to the test house without regard to the product(s) within which it is used. Case B – A terminal supplied as an integral part of a s
Scope: This International Standard applies to screw-type and screwless-type clamping units of any material for connecting devices, either as separate entities or as integral parts of products, for the connection of unprepared electrical aluminium (bare or plated) and copper-clad aluminium conductors (complying with IEC 228), rigid (solid and stranded), having a cross-sectional area of 2,5 mm2 up to and including 50 mm2, and equivalent AWG conductors,with a rated voltage not exceeding 1 000 V a.c. up to and including 1 000 Hz, and 1 500 V d.c. This standard also applies to aluminium bodied clamping units for the connection of rigid (solid and stranded) and flexible copper conductors (complying with IEC 228), 0,5 mm 2 up to and including 35 mm2 and equivalent AWG conductors. It contains the minimum requirements applicable to clamping units primarily suitable for connecting conductors. This standard does not apply to clamping units: a) for connection by crimping, brazing, soldering or welding; b) for data and signalling circuits; c) for flat quick-connect terminations, insulation piercing-type connections or twist-on connecting devices, for which separate pa rts exist or are under consideration. NOTES 1 In the USA and Canada, subclause 5.5.2 covering treatment of the specimens and conductors to be tested is not acceptable. 2 Flexible aluminium conductors are not covered by this standard. Upon the development of such conductors their inclusion will be considered.
Contents:
- FOREWORD
- INTRODUCTION
- 1 Scope
- 2 Normative references
- 4 General
- 5 General requirements for tests
- 7 Marking
- 8 Main characteristics
- 9 Connection of conductors
- 10 Constructional requirements
- 11 Tests
- 12 Resistance to corrosion