Safety of transformers, reactors, power supply units and combinations thereof – Part 2-7: Particular requirements and tests for transformers and power supply units for toys
Introduction: IEC TC 96 has a group safety function in accordance with IEC Guide 104 for transformers other than those intended to supply distribution networks, in particular transformers and power supply units intended to allow the application of protective measures against electric shock as defined by TC 64, but in certain cases including the limitation of voltage and horizontal safety function for SELV, in accordance with IEC 60364-4-41. The group safety function (GSF) is used because of responsibility for safety extra-low voltage (SELV) in accordance with IEC 61140:2016, 5.2.6 and IEC 60364-4-41:2005, 414.3.1 or control circuits in accordance with IEC 60204-1:2016, 7.2.4. The group safety function is used for each part of IEC 61558-2 because different standards of the IEC 61558 series can be combined in one construction but in certain cases with no limitation of rated output power. For example, an auto-transformer in accordance with IEC 61558-2-13 can be designed with a separate SELV-circuit in accordance with the particular requirements for IEC 61558-2-6 relating to the general requirements of IEC 61558-1.
Scope: Replacement: This part of IEC 61558 deals with safety aspects of transformers for toys and power supplies incorporating transformers for toys such as electrical, thermal and mechanical safety. This Part 2-7 is applicable to transformers for toys and power supplies incorporating both transformers for toys and electronic circuits. This Part 2-7 is not applicable to external circuits and their components intended to be connected to the input terminals, output terminals or socket-outlets of the transformers and power supplies. This Part 2-7 applies to stationary and portable, single-phase, air-cooled (natural or forced), transformers for toys and power supplies incorporating transformers for toys, having a rated supply voltage not exceeding 250 V a.c., a rated supply and internal operating frequency not exceeding 500 Hz, a rated output not exceeding 200 VA and a rated output current not exceeding 10 A. This Part 2-7 is applicable to independent transformers and transformers for specific use. This Part 2-7 is applicable to dry-type transformers for toys. The windings may be encapsulated or non-encapsulated. The no-load output voltage does not exceed 33 V a.c. for transformers for toys and power supplies incorporating transformers for toys, or 46 V ripple-free d.c. for power supplies incorporating transformers for toys, and the rated output voltage does not exceed 24 V a.c. for transformers and power supplies, or 33 V ripple-free d.c. for power supplies. In general, this Part 2-7 does not take into consideration children playing with the transformers for toys and power supplies incorporating transformers for toys. NOTE 1 Attention is drawn to the following: – for transformers for toys and power supplies incorporating transformers for toys intended to be used in vehicles, on board ships, and aircraft, additional requirements (from other applicable standards, national rules, etc.) may be necessary; measures to protect the enclosure and the components inside the enclosure against external influences such as fungus, vermin, termites, solar-radiation, and icing should also be considered; – the different conditions for transportation, storage, and operation of the transform
Contents:
- FOREWORD
- INTRODUCTION
- Scope