Low-voltage surge protective devices – Part 31: Requirements and test methods for SPDs for photovoltaic installations
Introduction: This part of IEC 61643 addresses safety and performance tests for surge protective devices (SPDs) to be installed on the DC side of photovoltaic installations to protect against induced and direct lightning effects. There are three classes of tests: 1) The Class I test is intended to simulate partial conducted lightning current impulses. SPDs subjected to Class I test methods are generally recommended for locations at points of high exposure, e.g., line entrances to buildings protected by lightning protection systems. 2) SPDs tested to Class II or Class III test methods are subjected to impulses of shorter duration. 3) SPDs are tested on a “black box” basis as far as possible. Tests take into account that photovoltaic generators: behave like current generators, that their output current depends on the incident light intensity and temperature, that their short-circuit current is slightly higher than the operating output current, are connected in series and/or parallel combinations leading to a great variety of voltages, currents and powers from a few hundreds of W (in residential installations) to several MW (photovoltaic fields). The specific electrical parameters of PV installations on the DC side require specific test requirements for SPDs. IEC 61643-32 addresses the selection and application principles of SPDs in practical situations for PV application (work in progress).
Scope: This part of IEC 61643 is applicable to Surge Protective Devices (SPDs), intended for surge protection against indirect and direct effects of lightning or other transient overvoltages. These devices are designed to be connected to the DC side of photovoltaic installations rated up to 1 500 V DC. These devices contain at least one non-linear component and are intended to limit surge voltages and divert surge currents. Performance characteristics, safety requirements, standard methods for testing and ratings are established. SPDs complying with this standard are exclusively dedicated to be installed on the DC side of photovoltaic generators and the DC side of inverters. SPDs for PV systems with energy storage (e.g. batteries, capacitor banks) are not covered. SPDs with separate input and output terminals that contain specific series impedance between these terminal(s) (so called two-port SPDs according to IEC 61643-11:2011) are not covered. SPDs compliant with this standard are designed to be permanently connected where connection and disconnection of fixed SPDs can only be done using a tool. This standard does not apply to portable SPDs NOTE 1 In general SPDs for PV applications do not contain a specific series impedance between the input/output terminals due to power efficiency considerations. NOTE 2 Wherever reference is made to the electric power system or the power system within this document, this refers to the DC side of the photovoltaic installation.
Contents:
- FOREWORD
- INTRODUCTION
- Scope