Calibration of fibre optic chromatic dispersion test sets

Introduction: 0.1 Chromatic dispersion in optical fibres Chromatic dispersion is the variation with optical light wavelength of the light propagation delay time in a length of fibre. This variation can cause bandwidth limitation in the fibre when used to transmit communication signals. For a more detailed explanation, refer to Annex D and IEC 60793-1-42. 0.2 Chromatic dispersion (CD) test sets CD test sets are used to measure the chromatic dispersion properties of optical fibres and typically comprise an optical source of known wavelength(s), a fibre light input coupling and output coupling means, optical detection means, and electronic or optical means of determining the optical delay or dispersion at the source wavelength. There are several variants each requiring slightly different calibration techniques. Refer to Annex D for further details. In general, all CD test sets produce an output of fibre delay or dispersion versus the light wavelength, typically in graphical form. In essence, all CD test sets operate with wavelength as a programmed (independent) variable, usually the abscissa (x-axis) and dispersion or time delay as the ordinate (y-axis) as a measured (dependent) variable. By their nature, fibre chromatic dispersion measurements require multiple wavelengths to be programmed. Even in the case of a single dispersion point obtained using the differential phase shift method, two separate wavelength values are used. It is also typical to expect a wide range of dispersion values ove

Scope: This document provides standard procedures for the calibration of optical fibre chromatic dispersion (CD) test sets. This document is applicable to all types of CD test sets, with the exception that measurements on multimode optical fibres are excluded. The purpose of this document is to define a standard procedure for calibrating optical fibre chromatic dispersion (CD) test sets. The detailed calibration steps used vary according to the measurement technique used in the CD test set. Whilst it is acknowledged that chromatic dispersion also occurs in multimode fibre and this fibre can be measured on many CD test sets, this document will restrict discussion to single mode fibre measurements applications only. The purpose of the procedures outlined in this document is to focus manufacturers and users of CD test sets toward the reduction of measurement uncertainty in chromatic dispersion determination in optical fibres under all applicable conditions. The procedures apply to calibration laboratories and to the manufacturers or users of CD test sets for the purpose of a) calibrating CD test sets, and b) evaluating the level of performance of the instrument. Use of the procedures also allows correct evaluation of CD test set uncertainty, relative and traceable to appropriate (for example, national) standards.

Contents:

  • FOREWORD
  • Introduction
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 61744-2023 PDF

IEC 61744-2023 PDF

$163.93 $327.86