Superconductivity – Part 3: Critical current measurement – DC critical current of Ag- and/or Ag alloy-sheathed Bi-2212 and Bi-2223 oxide superconductors
Introduction: In 1986 J.G. Bednorz and K.A. Mueller discovered that some Perovskite type Cu-containing oxides show superconductivity at temperatures far above those which metallic superconductors have shown. Since then, extensive R & D work on high-temperature oxide superconductors has been and is being made worldwide, and its application to high-field magnet machines, low-loss power transmission, electronics and many other technologies is in progress [1].1) Fabrication technology is essential to the application of high-temperature oxide super- conductors. Among high-temperature oxide superconductors developed so far, BiSrCaCu oxide (Bi-2212 and Bi-2223) superconductors have been the most successful at being fabricated into wires and tapes of practical length and superconducting properties. These conductors can be wound into a magnet to generate a magnetic field of several tesla [2]. It has also been shown that Bi-2212 and Bi-2223 conductors can substantially raise the limit of magnetic field generation by a superconducting magnet [3]. In summer 1993, VAMAS-TWA16 started working on the test methods of critical currents in Bi-oxide superconductors. In September 1997, the TWA16 worked out a guideline (VAMAS guideline) on the critical current measurement method for Ag-sheathed Bi-2212 and Bi-2223 oxide superconductors. This pre-standardization work of VAMAS was taken as the base for the IEC standard, described in the present document, on the dc critical current test method of Ag-sheathed Bi-2
Scope: This part of IEC 61788 covers a test method for the determination of the dc critical current of short and straight Ag- and/or Ag alloy-sheathed Bi-2212 and Bi-2223 oxide superconductors that have a monolithic structure and a shape of round wire or flat or square tape containing mono- or multicores of oxides. This method is intended for use with superconductors that have critical currents less than 500 A and n-values larger than 5. The test is carried out with and without an applying external magnetic field. For all tests in a magnetic field, the magnetic field is perpendicular to the length of the specimen. In the test of a tape specimen in a magnetic field, the magnetic field is parallel or perpendicular to the wider tape surface (or one surface if square). The test specimen is immersed either in a liquid helium bath or a liquid nitrogen bath during testing. Deviations from this test method that are allowed for routine tests and other specific restrictions are given in this standard.
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 10 Calculation of results
- 11 Test report