IEC 61829-2015 PDF

IEC 61829-2015 PDF

Photovoltaic (PV) array-On-site measurement of current-voltage characteristics

$72.51 $145.02 -50%
Product Code: IEC 61829
Stock In Stock
Edition: 2.0
Published: 10/2015
Number of Pages: 38
File Size: 1 file, 459 Bytes

Available Options

Product Description

Photovoltaic (PV) array – On-site measurement of current-voltage characteristics

Introduction: The performance of photovoltaic (PV) systems over their decades-long life time is determined by comparing measured power production with the expected production as estimated from recorded weather conditions. Continuous measurements of system- or subsystem-level operating output can detect underperforming arrays but are not well suited for tracking degradation with any accuracy, or for identifying the weaknesses or failure modes that may exist within the array. Field I-V curve measurements offer a practical method of in situ benchmarking or troubleshooting for modules, strings and arrays. This International Standard specifies methods and approaches for field I-V curve measurements and calculations, and includes guidance for addressing the uncertainties associated with measurement devices and array configurations. Consistent and proper application of I-V curve measurement procedures helps to ensure that a PV system’s performance is adequately characterized over time.

Scope: This International Standard specifies procedures for on-site measurement of flat-plate photovoltaic (PV) array characteristics, the accompanying meteorological conditions, and use of these for translating to standard test conditions (STC) or other selected conditions. Measurements of PV array current-voltage (I-V) characteristics under actual on-site conditions and their translation to reference test conditions (RTC) can provide: data for power rating or capacity testing; verification of installed array power performance relative to design specifications; detection of possible differences between on-site module characteristics and laboratory or factory measurements; detection of possible performance degradation of modules and arrays with respect to on- site initial data; detection of possible module or array failures or poor performance. For a particular module, on-site measurements translated to STC can be directly compared with results previously obtained in a laboratory or factory for that module. Corrections for differences in the spectral or spatial response of the reference devices may need to be assessed as specified in IEC 60904. On-site array measurements are affected by diode, cable, and mismatch losses, soiling and shading, degradation due to aging, and other uncontrolled effects. Therefore, they are not expected to be equal to the product of the number of modules and the respective module data. If a PV array is formed with sub-arrays of different tilt, orientation, technology, or electrical configuration, the procedure specified in this International Standard is applied to each unique PV sub-array of interest.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 61829-2015 PDF

IEC 61829-2015 PDF

$72.51 $145.02