IEC 61869-13-2021 PDF

IEC 61869-13-2021 PDF

Instrument transformers-Part 13: Stand-alone merging unit (SAMU)

$239.59 $479.18 -50%
Product Code: IEC 61869-13
Stock In Stock
Edition: 1.0
Published: 02/2021
Number of Pages: 146
File Size: 1 file, 7 Bytes

Available Options

Product Description

Instrument transformers – Part 13: Stand-alone merging unit (SAMU)

Introduction: General This document is an IEC 61869 series product standard which defines additional requirements for a stand-alone merging unit (SAMU). The general block diagram showing a typical SAMU application example is given in Figure 1301. Figure 1301 – Stand-alone merging unit (functional concept example) An application example showing a three-phase dead tank circuit breaker equipped with bushing type current transformers and a stand-alone merging unit mounted inside the breaker control cabinet is shown in Figure 1302. Figure 1302 – Stand-alone merging unit application example The SAMU output may be used by many devices and is therefore of interest to multiple technical committees in addition to TC 38, for example: TC 57: Power systems management and

Scope: Clause 1 of IEC 61869-1:2007 is replaced by the following: This part of IEC 61869 is a product standard and covers only additional requirements for stand- alone merging units (SAMUs) used for AC applications having rated frequencies from 15 Hz to 100 Hz. The digital output format specification is not covered by this document; it is standardized in IEC 61869-9 as an application of IEC 61850, which specifies the power utility communication architecture. This document covers SAMUs having standardized analogue inputs (for example: 1 A, 5 A, 3,25 V / √3 or 100 V / √3) provided by instrument transformers compliant with relevant product standards (e.g. IEC 61869-2 to IEC 61869-5, IEC 61869-7, IEC 61869-8, IEC 61869-10, IEC 61869-11, IEC 60044-1 to IEC 60044-6, IEC 60185, IEC 60186, IEEE C57.13), and aims to convert them to the digital output compliant with IEC 61869-9. Other input and output types are outside the scope of this document. Appropriate SAMU functionality can be combined with switchgear controller functionality defined in IEC 62271-3 or other IED functionality defined in IEC 60255 (all parts). Cyber security requirements are outside the scope of this document and are covered by the IEC 62351 series.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 61869-13-2021 PDF

IEC 61869-13-2021 PDF

$239.59 $479.18