Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-1: Determination of the detective quantum efficiency - Detectors used in radiographic imaging

$163.93 $327.86 -50%
Product Code: IEC 62220-1-1
Stock In Stock
Edition: 1.0
Published: 03/2015
Number of Pages: 78
File Size: 1 file, 817 Bytes

Available Options

Product Description

Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-1: Determination of the detective quantum efficiency - Detectors used in radiographic imaging

Introduction: DIGITAL X-RAY IMAGING DEVICES are increasingly used in medical diagnosis and are widely replacing conventional (analogue) imaging devices such as screen-film systems or analogue X-RAY IMAGE INTENSIFIER television systems. It is necessary, therefore, to define parameters that describe the specific imaging properties of these DIGITAL X-RAY IMAGING DEVICES and to standardize the measurement procedures employed. There is general consensus in the scientific world that the DETECTIVE QUANTUM EFFICIENCY (DQE) is the most suitable parameter for describing the imaging performance of a DIGITAL X- RAY IMAGING DEVICE. The DQE describes the ability of the imaging device to preserve the signal-to-noise ratio from the RADIATION FIELD to the resulting digital image data. Since in X- ray imaging, the NOISE in the RADIATION FIELD is intimately coupled to the AIR KERMA level, DQE values can also be considered to describe the dose efficiency of a given DIGITAL X-RAY IMAGING DEVICE. NOTE 1 In spite of the fact that the DQE is widely used to describe the performance of imaging devices, the connection between this physical parameter and the decision performance of a human observer is not yet completely understood [1], [3].1 NOTE 2 IEC 61262-5 specifies a method to determine the DQE of X-RAY IMAGE INTENSIFIERS at nearly zero SPATIAL FREQUENCY. It focuses only on the electro-optical components of X-RAY IMAGE INTENSIFIERS, not on the imaging properties as this standard does. As a consequence, the outpu

Scope: This part of IEC 62220 specifies the method for the determination of the DETECTIVE QUANTUM EFFICIENCY (DQE) of DIGITAL X-RAY IMAGING DEVICES as a function of AIR KERMA and of SPATIAL FREQUENCY for the working conditions in the range of the medical application as specified by the MANUFACTURER. The intended users of this part of IEC 62220 are manufacturers and well equipped test laboratories. NOTE 1 While not recommended, applying this standard to determine the DQE of digital X-ray imaging devices integrated in a clinical system is not excluded as long as the requirements as set in this standard are respected. Points of additional attention could be (for example but not exclusively) the establishment of the required RADIATION QUALITIES, minimizing influences of scattered and back-scattered radiation, accurate AIR KERMA measurements, positioning of the TEST DEVICE, presence of protective covers, removal of ANTI-SCATTER GRID. This Part 1-1 is restricted to DIGITAL X-RAY IMAGING DEVICES that are used for radiographic imaging such as, but not exclusively, CR systems, direct and indirect flat panel-detector based systems. It is not recommended to use this part of IEC 62220 for digital X-RAY IMAGE INTENSIFIER-based systems. NOTE 2 The use of this standard for X-RAY IMAGE INTENSIFER-based systems is discouraged based on the low frequency drop, vignetting and geometrical distortion present in these devices which may put severe limitations on the applicability of the measurement methods described in this standard. This part of IEC 62220 is not applicable to: DIGITAL X-RAY IMAGING DEVICES intended to be used in mammography or in dental radiography; slot scanning DIGITAL X-RAY IMAGING DEVICES; COMPUTED TOMOGRAPHY; devices for dynamic imaging (where series of images are acquired, as in fluoroscopy or cardiac imaging). NOTE 3 The devices noted above are excluded because they contain many parameters (for instance, beam qualities, geometry, time dependence, etc.) which differ from those important for RADIOGRAPHY. Some of these techniques are treated in other parts of the IEC 62220 standards (IEC 62220-1-2 and IEC 62220-1-3).

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 62220-1-1-2015 PDF

IEC 62220-1-1-2015 PDF

$163.93 $327.86