Electric cables – Spark-test method
Introduction: The practice of using spark-testers to detect defects in the insulation or sheathing layers of electric cables has been developed over many years of practical experience. The operation of the equipment using the verification method described in this standard has proved to be satisfactory. This method employs an artificial fault simulator and its performance has been shown to be comparable to that using operational efficacy tests involving the detection of artificially prepared defects (i.e. faults in the insulation/sheathing material) in lengths of cable.
Scope: The spark-test method specified in this standard is intended for the detection of defects in the insulation or sheathing layers of electric cables. For single-core cables with no outer metallic layer, the general process is accepted as being equivalent to subjecting samples of those cables to a voltage test in water. This standard specifies the operational requirements for the spark-test equipment, as well as the principal characteristics, functional parameters and calibration procedures for each type of test equipment. Types of voltage waveform For the purposes of this standard, the types of voltage waveform used for spark-testing are divided into the following groups: a.c. an alternating current (a.c.) voltage of approximately sine-wave form, at the industrial frequency of 40 Hz to 62 Hz; d.c. a direct current (d.c.) voltage; h.f. an alternating current (a.c.) voltage of approximately sine-wave form, at frequencies between 500 Hz and 1 MHz; pulsed a voltage waveform comprising a fast rise time and highly damped wave-tail, as defined in 4.2. NOTE Provided the manufacturer can demonstrate equivalent effectiveness, h.f. voltages at frequencies below 500 Hz may be used. Procedure The insulated conductor or sheathed cable shall be passed through an electrode energized at the test voltage. The method detailed in this standard provides for the application of a.c., d.c., h.f. and pulsed voltages. The requirements for voltage waveform, frequency and test voltage are given in 4.2 and Clause 5. The maximum speed at which the cable shall pass through the electrode is determined by the minimum residence time specified in 4.6. When used as an alternative to a voltage test in water, it is recommended that the test shall be restricted to layer thicknesses not greater than 2,0 mm and to a.c. and d.c. test voltages unless otherwise specified in the cable standard. Only the a.c. or d.c. voltage waveforms shall be used. The requirements are not applicable to cable insulation having a rated voltage (U0) greater than 3 kV. Annex A provides recommended minimum voltages for each voltage waveform, to be used in the absence of any alternative voltages in the relevant cable standard. –
Contents:
- FOREWORD
- INTRODUCTION
- Scope