Determination of certain substances in electrotechnical products – Part 3-2: Screening – Fluorine, chlorine and bromine in polymers and electronics by combustion-ion chromatography (C-IC)
Introduction: The widespread use of electrotechnical products has drawn increased attention to their impact on the environment. In many countries all over the world this has resulted in the adaptation of regulations affecting wastes, substances and energy use of electrotechnical products. The use of certain substances (e.g. lead (Pb), cadmium (Cd), polybrominated diphenyl ethers (PBDEs) and phthalates) in electrotechnical products is a source of concern in current and proposed regional legislation. The purpose of the IEC 62321 series is therefore to provide test methods that will allow the electrotechnical industry to determine the levels of certain substances of concern in electrotechnical products on a consistent global basis. The first edition of IEC 62321-3-2 (2013) was published to address screening for total bromine. This document (revised edition of IEC 62321-3-2) describes the test methods to quantify halogen (fluorine, chlorine and bromine) in polymers and electronics by C-IC in the normative section and to quantify iodine (I) in an informative Annex D. In addition, information on oxygen bomb combustion-ion chromatography and oxygen flask-ion chromatography is provided in Annex A (informative) and Annex B (informative). WARNING – Persons using this document should be familiar with normal laboratory practice. This document does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user to establish appropriate safety and
Scope: Part 3-2 of IEC 62321 specifies the screening analysis of the total bromine (Br) in homogeneous materials found in polymers and electronics by using the analytical technique of combustion ion chromatography (C-IC). This part of IEC 62321 specifies the screening analysis of fluorine, chlorine and bromine in polymers and electronics using combustion-ion chromatography (C-IC). A C-IC screening analysis procedure for iodine can be found in Annex D. This test method has been evaluated for ABS (acrylonitrile butadiene styrene), EMC (epoxy moulding compound), PE (polyethylene) and PC (polycarbonate) within the concentration ranges as specified in Table 1, Table 2 and Table 3. (Detailed results are shown in Table E.1 to Table E.6, and in Annex F (Table F.1 and Table F.2). The use of this method for other types of materials or concentration ranges outside those specified below has not been evaluated. Table 1 – Tested concentration ranges for fluorine by C-IC in PC Substance/element Fluorine Polymer Unit of measure mg/kg PC Concentration or concentration range tested Table 2 – Tested concentration ranges for chlorine by C-IC in PE Substance/element Chlorine Polymer Unit of measure mg/kg PE Concentration or concentration range tested 102,2 Table 3 – Tested concentration ranges for bromine by C-IC in various materials Substance/element Bromine Parameter Unit of measure mg/kg Medium/material tested Polymer ABS EMC PE Concentration or concentration range tested 124 to 890 195 to 976 IEC 62321-3-2:2020 RLV © IEC 2020 – 9 – This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. This horizontal standard is primarily intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 108. One of the responsibilities of a technical committee is, wherever applicable, to make use of horizontal standards in the preparation of its publications. The contents of this horizontal standard will not apply u
Contents:
- FOREWORD
- INTRODUCTION
- Scope