IEC 62464-2-2010 PDF

IEC 62464-2-2010 PDF

Magnetic resonance equipment for medical imaging-Part 2: Classification criteria for pulse sequences

$50.44 $100.88 -50%
Product Code: IEC 62464-2
Stock In Stock
Edition: 1.0
Published: 11/2010
Number of Pages: 26
File Size: 1 file, 240 Bytes

Available Options

Product Description

Magnetic resonance equipment for medical imaging – Part 2: Classification criteria for pulse sequences

Introduction: Presently the MANUFACTURERS of MR EQUIPMENT use names for PULSE SEQUENCES which are adopted from the literature (e.g. SPIN-ECHO) or are defined by the MANUFACTURER (e.g. FISP: fast imaging with steady state precession). In the absence of a classification standard for PULSE SEQUENCES, the MANUFACTURER-specific terminology complicates comparison of PULSE SEQUENCES. The DICOM standard allows the inclusion of PULSE SEQUENCE information with digital MAGNETIC RESONANCE (MR) images. This information helps with the interpretation of images. However, the DICOM standard allows MANUFACTURER-specific terminology. This International Standard specifies a concise MANUFACTURER-independent classification scheme for MR imaging PULSE SEQUENCES. In terms of MR imaging, the PULSE SEQUENCE is a chronology of RF-pulses, switching of gradient fields and data acquisition with the intention to create one or more images. As the exact chronology determines the image contrast, image artefacts and other properties of the image, it is necessary to define a consistent and accurate PULSE SEQUENCE classification. The proposed PULSE SEQUENCE classification notation could be implemented as a new DICOM tag in addition to the existing MANUFACTURER-specific PULSE SEQUENCE name. This would facilitate end users’ access to this information. Implementation as a new tag would ensure backward compatibility.

Scope: This International Standard specifies the description of PULSE SEQUENCES of MAGNETIC RESONANCE imaging. NOTE The classification in this standard is suitable for: tender texts; image annotation; protocol definition; technical publications. This International Standard does not apply to MAGNETIC RESONANCE spectroscopy. The classification does not focus on image contrast (T1, T2, proton density), as this is defined by PULSE SEQUENCE parameters (e.g. repetition time, echo time) and is not a property of the PULSE SEQUENCE alone. The PULSE SEQUENCE classification does not specify the K-SPACE acquisition scheme, reconstruction algorithm or post-processing.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope