Medical electrical equipment – Exposure index of digital X-ray imaging systems – Part 1: Definitions and requirements for general radiography
Introduction: The direct connection between the level of detector exposure and optical density is well established in film-screen radiology. This is not the case in digital radiography, where almost always a constant image characteristic is achieved using automatic image processing. Consequently, deviations from the intended exposure, i.e., over- and underexposure, are not noticeable by a corresponding deviation in image brightness. While considerable underexposure results in an increased level of noise, the more alarming aspect (from a radiation protection point of view) is that overexposure cannot be recognized easily in the displayed image. Therefore, various manufacturers of digital radiography systems have introduced so-called exposure indicators for their equipment. These are numbers, determined from the original image data of each image taken, which allow conclusions about the level of the exposure at the image receptor. However, the exposure indicators are manufacturer or system specific, i.e. they differ for the systems of different manufacturers in their definition and scaling. A unified EXPOSURE INDEX for all digital radiography systems is needed to simplify its usage, e.g. for the establishment of exposure guidelines, particularly when systems of different manufacturers are used within the same department. This standard defines such a concept of the EXPOSURE INDEX. What is laid down here refers to the definition, the scale and the general requirements for the EXPOSURE INDEX. Th
Scope: This part of IEC 62494 specifies definitions and requirements for the EXPOSURE INDEX of images acquired with DIGITAL X-RAY IMAGING SYSTEMS. This standard is applicable to DIGITAL X-RAY IMAGING SYSTEMS used in general radiography for producing PROJECTION X-ray images for general applications, such as, but not exclusively: computed radiography (CR) systems based on stimulable phosphors; flat-panel detector based systems; charge-coupled device (CCD) based systems. Image intensifier based systems and systems for mammographic or dental application are not covered in this first edition. This standard defines the EXPOSURE INDEX only for images generated with a single IRRADIATION event. Images generated from multiple IRRADIATIONS (e.g., tomosynthetic or dual- energy images, multiple views on a single CR plate) are not covered.
Contents:
- FOREWORD
- INTRODUCTION
- Scope