Railway applications – Fixed installations – Particular requirements for AC switchgear – Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV
Introduction: The IEC 62505 series under the generic title Railway applications – Fixed installations – Particular requirements for a.c. switchgear, is divided as follows: Part 1: Circuit-breakers with nominal voltage above 1 kV. Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV. Part 3-1: Measurement, control and protection devices for specific use in a.c. traction systems – Application guide. Part 3-2: Measurement, control and protection devices for specific use in a.c. traction systems – Single-phase current transformers. Part 3-3: Measurement, control and protection devices for specific use in a.c. traction systems – Single-phase inductive voltage transformers. IEC 62505-2 has to be used in conjunction with IEC 62271-1:2007, IEC 62271-102:2001 and its Amendment 1:2011 and/or IEC 62271-103:2011, depending on the equipment involved. References in subclauses of IEC 62271-1, IEC 62271-102 and IEC 62271-103 need to be replaced by references to applicable subclauses in this standard as far as reasonably possible. References in subclauses in IEC 62271-102 need to be to IEC 62271-1 instead of IEC 60694. Where a particular clause of IEC 62271-1, IEC 62271-102 or IEC 62271-103 is not mentioned in this standard, that clause applies as far as reasonable. Where requirements relate exclusively to three-phase systems or to voltages outside those in use in traction systems, they are not applicable. Where this standard states "addition" or "replacement", the relevant
Scope: This part of IEC 62505 is applicable to single-pole, two-pole and three-pole alternating current (a.c.) disconnectors, earthing switches and switches which are: designed for indoor or outdoor fixed installations in tractions systems, and operated with an a.c. line voltage and frequency as specified in IEC 60850. NOTE 1 IEC 60850 specifies the a.c. traction systems: 15 kV 16,7 Hz, 12 kV 25 Hz, 12,5 kV, 20 kV also 25 kV with 50 Hz, and 12,5 kV, 20 kV, 25 kV also 50 kV with 60 Hz. NOTE 2 As rails of a.c. traction systems are typically connected to earth and included in the return current path, all phase-to-earth voltages will be within the tolerances as specified in IEC 60850. Nevertheless, phase-to-phase voltages are sometimes higher, e.g. in autotransformer systems.
Contents:
- FOREWORD
- INTRODUCTION
- Scope