Medical electrical equipment – Medical light ion beam equipment – Performance characteristics
Introduction: Standards containing safety requirements for LIGHT ION BEAM ME EQUIPMENT have been published separately by the IEC, details of which will be found in Clause 2. This document specifies methods of testing and methods of disclosure of performance of LIGHT ION BEAM ME EQUIPMENT intended for RADIOTHERAPY. It permits a direct comparison between the performance data of equipment of different MANUFACTURERS. This document was published subsequent to IEC 60601-2-64, Medical electrical equipment – Part 2-64: Particular requirements for the basic safety and essential performance of light ion beam medical electrical equipment. Many concepts useful to the reader of this document were described in that standard. Since this document does not contain safety requirements, it has not been numbered in the IEC 60601 publication series. It describes aspects of performance of LIGHT ION BEAM ME EQUIPMENT and the way in which they should be presented. It also includes test methods and conditions suitable for TYPE TESTS. These test methods are suggested test methods and alternative methods may be equally appropriate, but the SPECIFIED performance characteristics of LIGHT ION BEAM ME EQUIPMENT are related to these test methods and conditions. Tests SPECIFIED in this document are not necessarily appropriate for ensuring that any individual LIGHT ION BEAM ME EQUIPMENT conforms to the declared performance during the course of its working lifetime. In recognition of the diversity of equipment produced by M
Scope: This document applies to LIGHT ION BEAM ME EQUIPMENT when used, for therapy purposes, in human medical practice. This document applies to LIGHT ION BEAM ME EQUIPMENT which delivers LIGHT ION BEAMS with an ENERGY PER NUCLEON in the range 10 MeV/n to 500 MeV/n. This document describes measurements and test procedures to be performed by the MANUFACTURER of LIGHT ION BEAM ME EQUIPMENT but does not specify ACCEPTANCE TESTS. This document specifies test procedures for the determination and disclosure of performance characteristics, knowledge of which is necessary for proper selection, application, and use of LIGHT ION BEAM ME EQUIPMENT and which are to be declared in the ACCOMPANYING DOCUMENTATION together with the greatest deviation or variation to be expected under specific conditions in NORMAL USE. A format for presentation of performance values is given in Annex A. It is recognized that inaccuracies in the test methods can occur when assessing performance. However, it was felt preferable not to combine the errors into an overall performance tolerance but rather to keep them separate in the expectation that more accurate test methods will evolve. It is not intended that this document in any way inhibit the future development of new designs of equipment which may have operating modes and parameters different from those described herein, provided that such equipment achieves equivalent or better levels of performance for the TREATMENT of PATIENTS. This document applies to both ISOCENTRIC and non-ISOCENTRIC GANTRIES but many of the tests assume that the LIGHT ION BEAM ME EQUIPMENT has an ISOCENTRIC GANTRY. Where the equipment is non-ISOCENTRIC, the description of performance and test methods may be suitably adapted.
Contents:
- FOREWORD
- INTRODUCTION
- Scope