Management of alarm systems for the process industries (Commented Version)
Introduction: Purpose This International Standard addresses the development, design, installation, and management of alarm systems in the process industries. Alarm management includes multiple work processes throughout the alarm system management life cycle. This document defines the terminology and models to develop an alarm system, and it defines the work processes recommended to effectively maintain the alarm system throughout the life cycle. Ineffective alarm systems have often been cited as contributing factors in the investigation reports following major process incidents. This document is intended to provide a methodology that will result in the improved safety, quality, and operation in the process industries. The first edition of this document was adapted from ANSI/ISA-18.2-2009, Management of Alarm Systems for the Process Industries, an International Society of Automation (ISA) standard, and with due consideration of other guidance documents that have been developed throughout industry. This second edition has incorporated some changes made in ANSI/ISA-18.2-2016. This document is not the first effort to define terminology and practices for effective alarm systems. In 1999 the Engineering Equipment and Materials Users’ Association (EEMUA) issued Publication 191, Alarm Systems: A Guide to Design, Management and Procurement, with the 2nd edition published in 2007 and the 3rd edition published in 2013. In 2003 the User Association of Process Control Technology in Chemical and Pharmac
Scope: 1.1 General applicability This document specifies general principles and processes for the lifecycle management of alarm systems based on programmable electronic controller and computer-based human- machine interface (HMI) technology controls system and human-machine interfaces (HMI) 1 for facilities in the process industries. It covers all alarms to be presented to the operator through the control system, which includes alarms from basic process control systems, annunciators panels, packaged systems, and safety instrumented systems, fire and gas systems, and emergency response systems 2. The practices in this document are applicable to continuous, batch, and discrete processes. There can be differences in implementation to meet the specific needs based on process type. In jurisdictions where the governing authorities (e.g., national, federal, state, province, county, city) have established process safety design, process safety management, or other requirements, in addition to the requirements of this standard, these should be taken into consideration. 3 The primary function within the alarm system is to notify operators of abnormal process conditions or equipment malfunctions and support the response. The alarm systems can include both the basic process control system (BPCS) and the safety instrumented system (SIS), each of which uses measurements of process conditions and logic to generate alarms. Figure 1 illustrates the concepts of alarm and response dataflow through the alarm system. The alarm system also includes a mechanism for communicating the alarm information to the operator via an HMI, usually a computer screen or an annunciator panel. Additional functions of the alarm system are an alarm and event log, an alarm historian, and the generation of performance metrics for the alarm system. There are external systems that can use the data from the alarm system. Figure 1 is not intended to represent physical wiring. 4 IEC 62682:2022 CMV © IEC 2022 – 13 – NOTE 1 Packaged systems (e.g., refrigeration machines) can be included in the control system. NOTE 2 Panel can refer to annunciator panel or other panel types. NOTE 3 The lines are intended to represent da
Contents:
- FOREWORD
- INTRODUCTION
- Scope