IEC 62689-1-2016 PDF

IEC 62689-1-2016 PDF

Current and voltage sensors or detectors, to be used for fault passage indication purposes-Part 1: General principles and requirements

$239.59 $479.18 -50%
Product Code: IEC 62689-1
Stock In Stock
Edition: 1.0
Published: 05/2016
Number of Pages: 178
File Size: 1 file, 2 Bytes

Available Options

Product Description

Current and voltage sensors or detectors, to be used for fault passage indication purposes – Part 1: General principles and requirements

Introduction: 0.1 General The IEC 62689 series is a product family standard for current and voltage sensors or detectors, to be used for fault passage indication purposes by suitable devices or functions, indicated as fault passage indicator (FPI) or distribution substation unit (DSU), depending on their performances. Different names are used to indicate FPIs depending on the region of the world and on their functionalities concerning capability to detect different kinds of faults, for instance: fault detector; smart sensor; faulted circuit indicator (FCI); short circuit indicator (SCI); earth fault indicator (EFI); test point mounted FCI. combination of the above. Simpler versions, using only local information/signals and/or local communication, are called FPI, while very evolved versions are called DSU. The latter are explicitly designed for smart grids and based on IEC 60870-5 and IEC 61850 communication protocols. Compared to instrument transformers, digital communication technology is subject to on-going changes which are expected to continue in the future. Profound experience with deep integration between electronics and instrument transformers has yet to be gathered on a broader basis, as this type of equipment is not yet widespread in the industry. DSUs, besides FPI basic functions, may also optionally integrate additional auxiliary functions such as: voltage presence/absence detection for medium voltage (MV) network automation, with and without distributed energy resources presenc

Scope: This part of IEC 62689 defines the minimum requirements (therefore performances) and consequent classification and tests (with the exception of functional and communication ones) for fault passage indicators (FPIs) and distribution substation units (DSUs) (including their current and/or voltage sensors), which are, respectively, a device or a device/combination of devices and/or functions able to detect faults and provide indications about their localization. By localization of the fault is meant the fault position with respect to the FPI/DSU installation point on the network (upstream or downstream from the FPI/DSU’s location) or the direction of the fault current flowing through the FPI/DSU itself. The fault localization may be obtained directly from the FPI/DSU, or from a central system using information from more FPIs or DSUs, considering the features and the operating conditions of the electric system where the FPIs/DSUs are installed. In this part of IEC 62689, the FPI/DSU classification is specified in detail, in accordance with the first “core” classification defined in IEC 62689-2, which is explicitly focused on the description of electric phenomena and electric system response during faults, considering the most widely diffused distribution system architecture and fault typologies. Thus, IEC 62689-2 is mainly focused on helping users in the correct choice of FPIs/DSUs, whereas IEC 62689-1, IEC 62689-3 and IEC 62689-4 are mainly focused on FPI/DSU requirements, communication and testing procedures, respectively.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 62689-1-2016 PDF

IEC 62689-1-2016 PDF

$239.59 $479.18