Current and voltage sensors or detectors, to be used for fault passage indication purposes – Part 2: System aspects

Introduction: 0.1 General The IEC 62689 series is a product family standard for current and voltage sensors or detectors, to be used for fault passage indication purposes by proper devices or functions, indicated as fault passage indicator (FPI) or distribution substation unit (DSU), depending on their performances. Different names are used to indicate FPIs depending on the region of the world and on their functionalities concerning capability to detect different kinds of faults, for instance: fault detector; smart sensor; faulted circuit indicator (FCI); short circuit indicator (SCI); earth fault indicator (EFI); test point mounted FCI. combination of the above. Simpler versions, only using local information/signals and/or local communication, are called FPI, while very evolved versions are called DSU. The latter are explicitly designed for smart grids and based on IEC 60870-5 and IEC 61850 communication protocols.Compared to instrument transformers, digital communication technology is subject to on-going changes which are expected to continue in the future. Profound experience with deep integration between electronics and instrument transformers has yet to be gathered on a broader basis, as this type of equipment is not yet widespread in the industry. DSUs, besides FPI basic functions, may also optionally integrate additional auxiliary functions such as: voltage presence/absence detection for medium voltage (MV) network automation, with and without distributed energy resources presence (

Scope: This part of IEC 62689 describes electric phenomena and electric system behaviour during faults, according to the most widely diffused distribution system architecture and to fault typologies, to define the functional requirements for fault passage indicators (FPI) and distribution substation units (DSU) (including their current and/or voltage sensors), which are, respectively, a device or a device/combination of devices and/or of functions able to detect faults and provide indications about their localization. By localization of the fault is meant the fault position with respect to the FPI/DSU installation point on the network (upstream or downstream from the FPI/DSU’s location) or the direction of the fault current flowing through the FPI itself. The fault localization may be obtained directly from the FPI/DSU, or from a central system using information from more FPIs or DSUs, considering the features and the operating conditions of the electric system where the FPIs/DSUs are installed. This part of IEC 62689 is therefore aimed at helping users in the appropriate choice of FPIs/DSUs (or of a system based on FPI/DSU information) properly operating in their networks, considering adopted solutions and operation rules (defined by tradition and/or depending on possible constraints concerning continuity and quality of voltage supply defined by a national regulator), and also taking into account complexity of the apparatus and consequent cost. This part of IEC 62689 is mainly focused on system behaviour during faults, which is the “core” of FPI/DSU fault detection capability classes described in IEC 62689-1, where all requirements are specified in detail.

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 62689-2-2016 PDF

IEC 62689-2-2016 PDF

$186.00 $371.99