Electrical installations for lighting and beaconing of aerodromes –Safety secondary circuits in series circuits – General safety requirements
Introduction: With a few exceptions, aeronautical ground lighting is designed for series circuit technology operating with a constant current and a maximum input voltage of 5 000 V a.c. rms, including tolerances. The input voltage to the series circuit is constantly adjusted by the constant current regulator to maintain the series circuit current irrespective of the variations in the load. The properties and characteristics of the constant current regulators are provided in IEC 61822. Due to the structure of the series circuit, i.e. a series connection of all loads, the usual protective devices for personnel protection of an IT, TT or TN network cannot be applied. Aeronautical ground lighting is defined as any light provided as an aid to air navigation and as such is subject to specific requirements with respect to its resilience, availability, and serviceability levels. Therefore, insulation faults in the series circuit are often tolerated, and do not lead to the automatic disconnection of the electrical supply to the series circuit. In view of the above IEC 61821 states that no work of any kind is normally permitted on live series circuits without first conducting a suitable and sufficient Risk Assessment and using appropriate protective equipment according to IEC 61821. The electrical characteristics of the constant current series circuits are often confused with those of IT, TT or TN networks, i.e. constant input voltage, equipment connected in parallel, and a load-dependent current. I
Scope: This International Standard specifies protective provisions for the operation of lamp systems powered by series circuits in aeronautical ground lighting. The protective provisions described here refer only to secondary supply systems for loads that are electrically separated from the series circuit. This standard specifies the level of SELV, and alternatively PELV, under consideration of additional personnel protection during work on live secondary circuits by electrically skilled persons. This standard also covers the special operational features of aeronautical ground lighting and addresses the level of training and the requirements for maintenance procedures detailed in IEC 61821. The requirements and tests are intended to set a specification framework for system designers, users, and maintenance personnel to ensure a safe and economic use of electrical systems in installations for the beaconing of aerodromes. This standard complements existing IEC Airfield-Ground- Lighting (AGL) standards and can be used as a design specification.
Contents:
- FOREWORD
- INTRODUCTION
- Scope